We use cookies to distinguish you from other users and to provide you with a better experience on our websites. Close this message to accept cookies or find out how to manage your cookie settings.
To save content items to your account,
please confirm that you agree to abide by our usage policies.
If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your account.
Find out more about saving content to .
To save content items to your Kindle, first ensure [email protected]
is added to your Approved Personal Document E-mail List under your Personal Document Settings
on the Manage Your Content and Devices page of your Amazon account. Then enter the ‘name’ part
of your Kindle email address below.
Find out more about saving to your Kindle.
Note you can select to save to either the @free.kindle.com or @kindle.com variations.
‘@free.kindle.com’ emails are free but can only be saved to your device when it is connected to wi-fi.
‘@kindle.com’ emails can be delivered even when you are not connected to wi-fi, but note that service fees apply.
The purpose of this study is to evaluate variation in the treatment hold pattern and quantify its dosimetric impact in breath-hold radiotherapy, using fraction-specific post-treatment quality assurance.
Material and Methods
A patient with lung mets treated using intensity-modulated radiation therapy (IMRT) with active breath coordinator (ABC) was recruited for the study. Treatment beam hold conditions were recorded for all the 25 fractions. The linearity and reproducibility of the dosimetric system were measured. Variation in the dose output of unmodulated open beam with beam hold was studied. Patient-specific quality assurance (PSQA) was performed with and without beam hold, and the results were compared to quantify the dosimetric impact of beam hold.
Results
There was a considerable amount of variation observed in the number of beam hold for the given field and the monitor unit at which the beam held. Linearity and reproducibility of the dosimetric system were found within the acceptable limits. The average difference over the 25 measurements was 0·044% (0·557 to −0·318%) with standard deviation of 0·248.
Conclusion
Patient comfort with the ABC system and responsiveness to the therapist communication help to maintain consistent breathing pattern, in turn consistent treatment delivery pattern. However, the magnitude of dosimetric error is much less than the acceptable limits recommended by IROC. The dosimetric error induced by the beam hold is over and above the dose difference observed in conventional PSQA.
Recommend this
Email your librarian or administrator to recommend adding this to your organisation's collection.