Hostname: page-component-586b7cd67f-2brh9 Total loading time: 0 Render date: 2024-11-28T03:05:01.840Z Has data issue: false hasContentIssue false

Prolonged severe acute respiratory coronavirus virus 2 (SARS-CoV-2) viral shedding in lower-respiratory specimens of critically ill patients does not correlate with nasopharyngeal swab results

Published online by Cambridge University Press:  24 May 2022

Daniel M. Brailita*
Affiliation:
Division of Infectious Diseases, University of Nebraska Medical Center, Omaha, Nebraska
Allison M. Cushman-Vokoun
Affiliation:
Department of Pathology and Microbiology, University of Nebraska Medical Center, Omaha, Nebraska
Macy G. Wood
Affiliation:
Department of Pathology and Microbiology, University of Nebraska Medical Center, Omaha, Nebraska
Ann M. Crowley
Affiliation:
Department of Pathology and Microbiology, University of Nebraska Medical Center, Omaha, Nebraska
Sharleen A. Rapp
Affiliation:
Department of Pathology and Microbiology, University of Nebraska Medical Center, Omaha, Nebraska
Paul D. Fey
Affiliation:
Department of Pathology and Microbiology, University of Nebraska Medical Center, Omaha, Nebraska
Mark E. Rupp
Affiliation:
Division of Infectious Diseases, University of Nebraska Medical Center, Omaha, Nebraska
Angela L. Hewlett
Affiliation:
Division of Infectious Diseases, University of Nebraska Medical Center, Omaha, Nebraska
*
Author for correspondence: Dr. Daniel Brailita, E-mail: [email protected]
Rights & Permissions [Opens in a new window]

Abstract

Type
Research Brief
Copyright
© The Author(s), 2022. Published by Cambridge University Press on behalf of The Society for Healthcare Epidemiology of America

Early in the COVID-19 pandemic, our institution adopted a conservative approach for patients admitted with COVID-19 illness, maintaining isolation precautions for a total of 21 days from date of initial positive polymerase chain reaction (PCR) assay, unless test-based criteria for exiting isolation (2 negative PCR tests separated by >24 hours) was met. The COVID-19 infectious diseases team (COVID ID) evaluates patients who meet time-based criteria for discontinuation of isolation but are severely immunocompromised or remain critically ill, to provide expert consultation and to assist with decision making regarding duration of isolation.

Reports of prolonged viral shedding in severely immunosuppressed patients are available. Reference Aydillo, Gonzalez-Reiche and Aslam1Reference Tarhini, Recoing and Bridier-Nahmias3 There are also concerns regarding prolonged viral shedding in patients who remain critically ill, particularly because many of these patients remain intubated or undergo other aerosol-generating procedures. Reference Long, Zhao and Zeng4Reference Nomura, Kitagawa and Omori6 At our center, the COVID ID physician assesses patients who are 21 days from their initial positive test for clinical improvement and typically recommends repeat PCR testing of respiratory specimens in patients who remain critically ill. Reference Mowrer, Creager and Cawcutt7 In patients with positive PCR results, the cycle threshold value (Ct) is evaluated to make a better-informed determination on whether isolation can safely be discontinued. Generally, Ct ≥ 30 has been associated with the inability to recover viable SARS-CoV-2 virus. Reference Gniazdowski, Paul Morris and Wohl8,Reference Young, Ong and Ng9 A nasopharyngeal (NP) swab is the typical specimen for SARS-CoV-2 PCR; however, concerns have surfaced regarding the continued risk for viral replication in the lower respiratory tract in patients who remain critically ill and whether tracheal aspirates should be utilized in lieu of NP swabs.

Factors that increase the risk of nosocomial transmission of respiratory viruses include high community incidence rates, high viral load, greater symptoms when viral loads are high, proximity between people, duration of exposure, lack of maskings, and poor ventilation. Reference Klompas, Milton and Rhee10 Because continued viral shedding in the lower respiratory tract could represent continued risk for transmission and nosocomial outbreaks, we evaluated the correlation of Ct values from NP swabs and tracheal aspirates in critically ill patients who remain intubated or on assisted ventilation at least 21 days from their initial positive SARS-CoV-2 PCR as a quality improvement initiative to determine the utility of PCR of tracheal aspirates and to assist with decision making regarding discontinuation of isolation.

This analysis was performed on a small series of patients admitted to critical care units at University of Nebraska Medical Center/Nebraska Medical between October and December 2021. At that time, the δ (delta) variant (B.1.617.2) accounted for >99% of COVID-19 hospital admissions. Patients who had surpassed 21 days since their initial positive SARS-CoV-2 PCR but remained intubated or on assisted ventilation were evaluated by the COVID ID team according to routine protocol. Paired NP swabs and tracheal aspirates were collected for SARS-CoV-2 PCR. Tracheal aspirates were extracted on the KingFisher Flex Purification System (ThermoFisher, Waltham, MA) using the MagMAX Viral/Pathogen II (MVP II) nucleic acid isolation kit (ThermoFisher). Because of viscosity issues, samples were extracted in triplicate, using a 400-µL input volume and a 50-µL elution volume for each replicate. The extracted RNA was used for the detection of SARS CoV-2 RNA using a reverse-transcription, real-time PCR assay on the Applied Biosystems QuantStudio Dx Real-Time Instrument (ThermoFisher). The NP swabs in viral transport media were spun in a vortexer to mix the sample, then placed in aliquots (ie, 750 µL) in a second tube and loaded directly onto the Roche Cobas 6800 system (Roche Molecular Systems, Branchburg, NJ) for extraction and amplification using the SARS-CoV-2 assay. The Roche SARS-CoV-2 assay includes 2 targets for the qualitative detection of SARS-CoV-2: the orf1a gene, which is specific for SARS-CoV-2, and the E gene, a pansarbecovirus target.

We found a significant discrepancy between Ct values from NP swabs and tracheal aspirates in some patients, and our discordant results on paired NP and tracheal aspirate specimens (obtained within 24 hours of each other) are shown in Table 1.

Table 1. SARS-COV-2 PCR Results From Paired Tracheal Aspirate (TA) and Nasopharyngeal (NP) Specimens

Although sufficient evidence indicates that immunosuppressed individuals may shed SARS-CoV-2 for extended periods, critical illness may also result in prolonged viral shedding. Our results demonstrate that Ct values from lower-respiratory-tract specimens in patients who remain intubated or critically ill at day 21 from initial positive PCR may be low enough to be consistent with active viral replication, and these results do not necessarily correlate with results from NP swabs. This finding is concerning because nosocomial transmission of COVID-19 could occur as a result of discontinuing isolation in patients who continue to undergo aerosol-generating procedures and as a result of management of secretions by healthcare workers.

We recognize the limitations of our study related to very small sample size, the potential difference in Ct values from use of different types of samples and laboratory platforms, and the lack of viral cultures to confirm active viral replication. Furthermore, this evaluation was performed during the SARS-CoV-2 δ (delta) variant wave, and it may not be applicable to the SARS-CoV-2 (omicron) variant (B.1.1.529) or subsequent lineages. Despite these limitations, the discrepancy in Ct values in this small series was compelling enough for our institution to continue our practice of reviewing all critically ill, intubated patients at day 21 from initial positive PCR and to obtain tracheal aspirates to inform decisions regarding the need for continued isolation in the inpatient setting.

Acknowledgments

We acknowledge the hard work and dedication of the UNMC Infectious Diseases Division, infection prevention and clinical laboratory teams at Nebraska Medicine along with all frontline healthcare workers for all their efforts during this pandemic.

Financial support

No financial support was provided relevant to this article.

Conflicts of interest

All authors report no conflicts of interest relevant to this article.

References

Aydillo, T, Gonzalez-Reiche, AS, Aslam, S, et al. Shedding of viable SARS-CoV-2 after immunosuppressive therapy for cancer. N Engl J Med 2020;383:25862588.CrossRefGoogle ScholarPubMed
Baang, JH, Smith, C, Mirabelli, C, et al. Prolonged severe acute respiratory syndrome coronavirus 2 replication in an immunocompromised patient. J Infect Dis 2021;223:2327.CrossRefGoogle Scholar
Tarhini, H, Recoing, A, Bridier-Nahmias, A, et al. Long-term severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infectiousness among three immunocompromised patients: from prolonged viral shedding to SARS-CoV-2 superinfection. J Infect Dis 2021;223:15221527.CrossRefGoogle ScholarPubMed
Long, H, Zhao, J, Zeng, HL, et al. Prolonged viral shedding of SARS-CoV-2 and related factors in symptomatic COVID-19 patients: a prospective study. BMC Infect Dis 2021;21:1282.CrossRefGoogle ScholarPubMed
Munker, D, Osterman, A, Stubbe, H, et al. Dynamics of SARS-CoV-2 shedding in the respiratory tract depends on the severity of disease in COVID-19 patients. Eur Respir J 2021;58:2002724.CrossRefGoogle ScholarPubMed
Nomura, T, Kitagawa, H, Omori, K, et al. Duration of infectious virus shedding in patients with severe coronavirus disease 2019 who required mechanical ventilation. J Infect Chemother 2022;28:1923.CrossRefGoogle ScholarPubMed
Mowrer, CT, Creager, H, Cawcutt, K, et al. Evaluation of cycle threshold values at deisolation. Infect Control Hosp Epidemiol 2021. doi: 10.1017/ice.2021.132.Google ScholarPubMed
Gniazdowski, V, Paul Morris, C, Wohl, S, et al. Repeated coronavirus disease 2019 molecular testing: correlation of severe acute respiratory syndrome coronavirus 2 culture with molecular assays and cycle thresholds. Clin Infect Dis 2021;73:e860e869.CrossRefGoogle ScholarPubMed
Young, BE, Ong, SWX, Ng, LFP, et al. Viral dynamics and immune correlates of COVID-19 diseases severity. Clin Infect Dis 2021;73:e2932e2942.CrossRefGoogle Scholar
Klompas, M, Milton, DK, Rhee, C, et al. Current insights into respiratory virus transmission and potential implications for infection control programs: a narrative review. Ann Intern Med 2021;174:17101718.CrossRefGoogle ScholarPubMed
Figure 0

Table 1. SARS-COV-2 PCR Results From Paired Tracheal Aspirate (TA) and Nasopharyngeal (NP) Specimens