Hostname: page-component-cd9895bd7-dzt6s Total loading time: 0 Render date: 2024-12-27T12:38:20.815Z Has data issue: false hasContentIssue false

Effect of tumour involvement on activity determination of resin Yttrium-90 in selective internal radiation therapy of metastatic liver cancer

Published online by Cambridge University Press:  29 September 2022

Jun Li*
Affiliation:
Department of Radiation Oncology, Thomas Jefferson University, Philadelphia, PA 19107, USA
Yan Yu
Affiliation:
Department of Radiation Oncology, Thomas Jefferson University, Philadelphia, PA 19107, USA
Rani Anne
Affiliation:
Department of Radiation Oncology, Thomas Jefferson University, Philadelphia, PA 19107, USA
*
Author for correspondence: Jun Li, Department of Radiation Oncology, Thomas Jefferson University, 111 South 11th Street, Philadelphia, PA 19107, USA. E-mail: [email protected]
Rights & Permissions [Opens in a new window]

Abstract

Introduction:

The study was aimed to evaluate the effect of tumour involvement on resin Yttrium-90 (Y90) activity determination for metastatic liver cancer treatment.

Methods:

One hundred and two cases of resin Y90 microsphere treatment were retrospectively studied. Body surface area (BSA) method was used in the calculation of resin Y90 activity. The total activity (TA) was calculated as a summation of activities obtained from BSA-based calculation and tumour involvement (TI). TI and TA of each case were evaluated. The contributions of TI to TA were calculated with the ratio of TI/TA.

Results:

The average contribution of TI to TA was 4·1%. The contributions were < 5·8% in 75% of the cases, < 2·2% in 50% of the cases and < 1·0% in 25% of the cases.

Conclusions:

Overall the effect of tumour involvement on the activity determination was small. The activity calculation could be simplified by neglecting TI in 25% of the cases where the activity contribution from TI was less than 1%. Contouring tumour and liver structures for TI calculation could be avoided in these cases, and the efficiency of the workflow for resin Y90 procedures could be improved.

Type
Technical Note
Copyright
© The Author(s), 2022. Published by Cambridge University Press

Introduction

Radioembolisation using Y90 microspheres, i.e., selective internal radiation therapy (SIRT), is a promising treatment modality for liver cancer treatment. Reference Kennedy, Nag and Salem1 Glass based Y90 microsphere (TherasphereTM, Boston Scientific, Boston, USA) was approved by the Food and Drug Administration as Humanitarian Device for treating hepatocellular carcinoma, as a neoadjuvant to surgery or transplantation. Reference Salem, Gabr and Riaz2 Resin-based Y90 microsphere (SIR-Spheres™; Sirtex Medical Limited, NSW, Australia) was approved by the Food and Drug Administration for treating colorectal metastases. 3

In resin based Y90 procedures, body surface area (BSA) method or partition model method is often used to determine resin Y90 activity for a treatment. 3Reference Kim, Cohalan, Kopek and Enger7 Although more advanced dosimetric methods have been proposed, Reference Kim, Cohalan, Kopek and Enger7Reference Tong, Kao, Too, Chin, Ng and Chow9 the BSA method, a semi-empirical method, because of its simplicity, is popularly used for resin Y90 procedures.

In the BSA method, Y90 activity is determined by two components: the BSA and tumour involvement. The BSA is calculated with a patient’s height and weight, and the tumour involvement is calculated as the ratio between tumour volume and liver volume. To obtain the volumes, tumour and liver structures need to be contoured on 3D images (e.g., CT or MR). The contouring process usually is time-consuming, especially in the cases where there are multiple small tumours. In our institution, multi-departments are involved in Y90 procedures. Efficiency of Y90 procedure workflow (from activity calculation to delivery) often relies on the activity calculation process. In an emergent case, a quick turnaround from activity calculation to treatment delivery is needed. It is of interest to investigate how significant the contribution of tumour involvement is to the activity determination.

In this paper, a retrospective study was conducted to investigate the effect of tumour involvement on resin Y90 activity determination.

Methods

One hundred and two clinical cases were included in the study. The patients were treated in our institution in recent years. In our practice, the resin Y90 activities were determined using the BSA method. The activity (total activity TA) was calculated as Reference Bernardini, Smadja and Faraggi4

(1) $$TA(GBq) = BSA - 0.2 + TI$$

where

(2) $$BSA({m^2}) = 0.20247 \times H{(m)^{0.725}} \times W{(kg)^{0.425}}$$

TI is tumour involvement, H is patient height (m) and W is patient weight (kg).

(3) $$TI = {{{V_{\rm{T}}}\;} \over {{V_{\rm{L}}}}}$$

V T and V L are tumour volume and liver volume, respectively. When TI is applied in Eq. (1) as a component of the TA, it has the unit of GBq.

In our practice, tumour and liver structures were contoured by oncologists on MR or CT images in MIM software (MIM Software Inc., Cleveland, OH, USA). The volumes were calculated in MIM. To limit normal liver dose and lung dose, a reduction factor F total was applied to the TA. The default value was 25%. The treatments were lobar treatments. Y90 activities for each lobe (right or left lobe) treatment was calculated with TA, F total and a lobe reduction factor F lobe .

(4) $$A\left( {GBq} \right) = TA \times (1 - {F_{total}}) \times (1 - {F_{lobe}})$$

For a right lobe treatment, a lobe reduction factor of 30% was applied to the calculation. For a left lobe treatment, a lobe reduction factor of 70% was applied. The lobe reductions were made based on the approximation that right lobe and left lobe account for approximate 70% and 30% of liver volume (mass), respectively.

The partition model Reference Bernardini, Smadja and Faraggi4 was used to estimate normal liver dose D Liver and lung dose D Lung :

(5) $${D_{Liver}}\left( {Gy} \right) = {{49.67 \times \left( {1 - {F_{Lung}}} \right) \times A} \over {{M_{iver}} + {M_{Tumor}} \times \left( {R - 1} \right)}}$$
(6) $${D_{Lung}}\left( {Gy} \right) = {{49.67 \times A \times {F_{Lung}}} \over {{M_{Lung}}}}$$

F Lung is lung shunt fraction, M Liver and M Tumour are total liver mass and tumour mass, respectively, and R is the uptake ratio of tumour and normal liver. F Lung and R were obtained from Nuclear Medicine technetium-99m macro-aggregated albumin (99mTc MAA) studies. M Liver and M Tumour were calculated with liver volume and tumour volume, with an assumed density of 1·03 g/cm3, Reference Lewandowski and Salem10 M Lung was assumed to be 1 kg. 3

Y90 is a daughter product of Sr90. Metyko et al’s study Reference Metyko, Erwin, Poston and Jimenez11 showed that the measured activity ratio between Sr90 and Y90 in SIR-Spheres was ∼3 × 10–9. The content of Sr90 in SIR-Spheres is negligible. Dose contribution of SIR-Spheres is primarily from Y90.

In our practice, tolerance doses of 35 Gy for liver and 8 Gy for lung were used. The tolerance doses were dose limits considered in the activity determination to limit the Y90 activity to avoid causing toxicities in the liver and lung. They were defined based on the literature recommendation Reference Lau, Kennedy and Kim12 and our institutional discussion. Lau et al recommended the dose limits of 50 Gy and 20 Gy to normal liver and lung, respectively. Reference Lau, Kennedy and Kim12 Considering that a default 25% reduction was applied to the calculated activity in our SIRT procedures, we used 35 Gy as the normal liver dose limit for a whole liver. We used a lower lung dose limit 8 Gy in our SIRT procedures. If accumulated normal liver dose and lung dose (i.e., the doses accumulated from both right lobe and left lobe treatments) were within the tolerances, the calculated activity A was then used for the treatment. If any of the doses exceeded the tolerances, the reduction factor F total was adjusted to lower the dose to be within the tolerances.

To study the effect of TI on activity determination, we evaluated the TI and TA in the 102 cases. The ratio of TI/TA was calculated, which reflected the contributions of TI to TA.

Results

Figure 1 shows tumour (cyan) and liver (magenta) contours delineated in MR images in a case. Each tumour was contoured and all tumour volumes were added up to generate a total tumour volume. The total tumour volume and liver volume were used in the activity calculation. Although there were multiple tumours in this case, the TI was only 0·02. In the activity calculation, the contribution of TI to TA was only 1%.

Figure 1. Tumour (cyan) and liver (magenta) structures contoured for activity calculation. The contribution of TI to total activity TA was 1% in this case.

Figure 2 shows a boxplot of TI and TA of the 102 cases. TI ranged from 0·003 to 0·383 GBq (mean: 0·075; standard deviation: 0·086), and TA ranged from 1·276 to 2·577 GBq (mean: 1·786; standard deviation: 0·259). Overall, the magnitudes of TI were very small compared to TA.

Figure 2. Tumour involvement TI and total activity TA of 102 cases.

Figure 3 shows a boxplot of ratio of TI and TA. Among the 102 cases, the contributions of TI to TA ranged from 0·2% to 22·2%, with an average contribution of 4·1% (standard deviation 4·4%).The contributions were less than 5·8% in 75% of the cases, less than 2·2% in 50% of the cases, and less than 1·0% in 25% of the cases.

Figure 3. Ratio of tumour involvement TI and total activity TA, TI/TA, of 102 cases.

Table 1 lists the statistical results.

Table 1. TI, TA and TI/TA of the 102 cases

Discussion

In the BSA method, tumour and liver structures need to be contoured in order to calculate TI for determining TA. Our study showed that in 25% of the 102 cases studied, TI contributed less than 1% to the TA. It is implied that the BSA method could be simplified, that is, TI could be neglected in the activity calculation in these cases, and contouring tumour and liver structures, which was time-consuming, could be avoided.

In our institution, multi-departments are involved in Y90 procedures: radiation oncologists contour tumour and liver structures for determining tumour involvement, medical physicists calculate Y90 activity using a patient’s height and weight and tumour involvement, a lab prepares resin Y90 microsphere vials for treatment following a prescription based on the activity calculation, and interventional radiologists deliver the treatment. The efficiency of the procedure workflow (from activity calculation to delivery) often relies on the activity calculation process, which relies on the contouring process for tumour involvement determination. In emergent cases, a quick turnaround from activity calculation to treatment delivery is needed. If the structure contouring could be avoided with minimal activity deviations (< 1%) in an emergent case, the activity determination process could be expedited and the efficiency of the workflow for resin Y90 procedures could be improved. In the emergent cases where the volume contouring is avoided, lung dose still can be estimated because the lung dose calculation does not involve the liver and tumour volumes. In our practice, patients have treatments to right lobe and left lobe, respectively. The two treatments are about one month apart. If the volume contouring is avoided due to emergency (it will be in the first treatment if it happens), the liver and tumour will be contoured after the emergent procedure to estimate the normal liver dose of the first treatment. The activity of the second treatment will be adjusted if needed, to limit the total liver dose to be within the tolerance. As in other cases, both lung dose and normal liver dose will be estimated.

Figure 4 shows TI/TA as a function of TI. TI/TA varied almost linearly with TI. With the fitted linear curve, one can estimate the deviations caused by neglecting TI in the activity calculation. In our institution, radiology reports include an estimation of tumour involvement. The estimation of tumour involvement could be used with the curve to predict potential deviations caused by neglecting TI in the calculation. The prediction could be used to determine if TI can be neglected (i.e., structure contouring can be avoided) with minimal deviations or not.

Figure 4. TI/TA as a function of TI.

Conclusions

The study showed that overall the effect of tumour involvement on the activity determination was small. TI could be neglected in the activity determination in 25% of the cases in the study where the activity contribution from TI was less than 1%. Avoiding contouring processes would bring improvement of the workflow efficiency in emergent situations where a quick turnaround from activity calculation to treatment delivery is needed.

Acknowledgements

None.

Financial support

This research received no specific grant from any funding agency, commercial or not-for-profit sectors.

Conflict of interest

The authors declare none.

Ethical standards

The authors assert that all procedures contributing to this work comply with the ethical standards of Thomas Jefferson University and relevant national guidelines on human experimentation in USA and with the Helsinki Declaration of 1975, as revised in 2008.

References

Kennedy, A, Nag, S, Salem, R et al. Recommendations for radioembolization of hepatic malignancies using Yttrium-90 microsphere brachytherapy: a consensus panel report from the radioembolization brachytherapy oncology consortium. Int J Radiat Oncol Biol Phys 2007; 68 (1): 1323.CrossRefGoogle ScholarPubMed
Salem, R, Gabr, A, Riaz, A et al. Institutional decision to adopt Y-90 as primary treatment for HCC informed by a 1000-patient 15-year experience. Hepatology 2017; 68 (4): 14291440.CrossRefGoogle Scholar
SIRS-Spheres Yttrium-90 microspheres package insert. https://www.sirtex.com/us/products/sir-spheres-y-90-resin-microspheres/about-sir-spheres/approved-indication/. Accessed on 10th March 2022.Google Scholar
Bernardini, M, Smadja, C, Faraggi, M et al. Liver Selective Internal Radiation Therapy with (90)Y resin microspheres: comparison between pre-treatment activity calculation methods. Phys Med 2014; 30 (7): 752764. doi: 10.1016/j.ejmp.2014.05.004 CrossRefGoogle ScholarPubMed
Ahmadzadehfar, H, Biersack, HJ, Ezziddin, S. Radioembolization of liver tumors with yttrium-90 microspheres. Semin Nucl Med 2010; 40 (2):105121. doi: 10.1053/j.semnuclmed.2009.11.001 CrossRefGoogle ScholarPubMed
Kao, YH, Tan, EH, Ng, CE, Goh, SW. Clinical implications of the body surface area method versus partition model dosimetry for yttrium-90 radioembolization using resin microspheres: a technical review. Ann Nucl Med 2011; 25 (7):455461. doi: 10.1007/s12149-011-0499-6 CrossRefGoogle ScholarPubMed
Kim, SP, Cohalan, C, Kopek, N, Enger, SA, A guide to 90Y radioembolization and its dosimetry, Phys Med 2019; 68: 132145.CrossRefGoogle ScholarPubMed
Tafti, BA, Padia, SA. Dosimetry of Y-90 microspheres utilizing Tc-99m SPECT and Y-90 PET. Semin Nucl Med 2019; 49 (3):211217. doi: 10.1053/j.semnuclmed.2019.01.005 CrossRefGoogle ScholarPubMed
Tong, AK, Kao, YH, Too, CW, Chin, KF, Ng, DC, Chow, PK. Yttrium-90 hepatic radioembolization: clinical review and current techniques in interventional radiology and personalized dosimetry. Br J Radiol 2016; 89 (1062): 20150943. doi: 10.1259/bjr.20150943 CrossRefGoogle Scholar
Lewandowski, RJ, Salem, R. Yttrium-90 radioembolization of hepatocellular carcinoma and metastatic disease to the liver. Semin Intervent Radiol 2006; 23 (1): 6472. doi: 10.1055/s-2006-939842 CrossRefGoogle Scholar
Metyko, J, Erwin, W, Poston, J Jr, Jimenez, S. 90Sr content in 90Y-labeled SIR-spheres and Zevalin. Health Phys 2014; 107 (5): S177S180. doi: 10.1097/HP.0000000000000171 CrossRefGoogle ScholarPubMed
Lau, WY, Kennedy, AS, Kim, YH, et al Patient selection and activity planning guide for selective internal radiotherapy with yttrium-90 resin microspheres. Int J Radiat Oncol Biol Phys 2012; 82: 401407.CrossRefGoogle ScholarPubMed
Figure 0

Figure 1. Tumour (cyan) and liver (magenta) structures contoured for activity calculation. The contribution of TI to total activity TA was 1% in this case.

Figure 1

Figure 2. Tumour involvement TI and total activity TA of 102 cases.

Figure 2

Figure 3. Ratio of tumour involvement TI and total activity TA, TI/TA, of 102 cases.

Figure 3

Table 1. TI, TA and TI/TA of the 102 cases

Figure 4

Figure 4. TI/TA as a function of TI.