Hostname: page-component-586b7cd67f-l7hp2 Total loading time: 0 Render date: 2024-11-28T21:42:17.963Z Has data issue: false hasContentIssue false

Aerosol distribution in the cabin and cockpit of an ambulance helicopter

Published online by Cambridge University Press:  10 June 2020

Sebastian Schulz-Stübner*
Affiliation:
German Consulting Center for Infection Prevention and Control [Deutsches Beratungszentrum für Hygiene (BZH GmbH)], Freiburg, Germany
Jürgen Henker
Affiliation:
DRF Stiftung Luftrettung gemeinnützige AG, Filderstadt, Germany
Jörg Braun
Affiliation:
DRF Stiftung Luftrettung gemeinnützige AG, Filderstadt, Germany
Raimund Kosa
Affiliation:
DRF Stiftung Luftrettung gemeinnützige AG, Filderstadt, Germany
*
Author for correspondence: Sebastian Schulz-Stübner, E-mail: [email protected]
Rights & Permissions [Opens in a new window]

Abstract

Type
Letter to the Editor
Copyright
© 2020 by The Society for Healthcare Epidemiology of America. All rights reserved.

To the Editor—Even before the COVID-19 pandemic, when our study was planned, the question of potential spread of droplets or airborne particles from the patient in the cabin of an air ambulance helicopter into the cockpit was eminent. Transportation of patients with aerogenously transmitted diseases in helicopters is increasingly required, and personal protective equipment cannot be worn by the pilot to the same degree as the medical crew. Also, disinfection of aeronautic equipment in the cockpit is cumbersome. Reference Schulz-Stübner, Kosa, Henker, Mattner and Wendel1 Therefore, we developed an experimental model to simulate aerosol distribution within the helicopter on the ground and in flight with a worst-case “airborne spread” scenario and a clinically relevant “short, intermittent droplet spread” scenario.

Material and Methods

The project was approved by the Wissenschaftlicher Arbeitskreis der DRF Stiftung Luftrettung gemeinnützige AG, WAK-ID 24 (Scientific Review Committee). A Cirrus 2 nebulizer (Intersurgical GmbH, Siegburger Str. 39, 53757 Sankt Augustin, Germany) was filled with a fluorescent marker fluid (UV-Tinte 4887, Flockenhaus GmbH KG, Frankfurter Str 536124 Eichenzell–Fulda, Germany) and positioned at the head of the patient stretcher, which was positioned at a 30° angle. For the worst-case scenario, aerosol was produced for 60 seconds with a flow of 8 L per minute every 5 minutes during flight or on the ground for 30 minutes and for 10 seconds in the short, intermittent scenario on 5 occasions with EC 135 and H 145 Airbus helicopters (Industriestrasse 4, 86609 Donauwörth, Germany) with and without a curtain separating the cockpit from the cabin. In the ground simulation, a test scenario with open aft doors and wind (simulated by a fan) directed into the cabin was added. Aerosol distribution was visualized with ultraviolet light, and the experiment was videotaped. The surface sedimentation was documented using serial photographs.

Results

Figure 1 gives an impression of the turbulent, undirected distribution of the aerosol. The aerosol filled the cabin on the ground and in flight, independent of helicopter type, ventilation settings, and flight maneuvers, resulting in sedimentation on all surfaces around the patient in the worst-case scenario. Without a curtain, sedimentation on aeronautic equipment in the cockpit occurred (Fig. 1b); with a curtain, sedimentation was found on the curtain but not in the cockpit.

Fig. 1. (a) The setup to visualize the stream of marked aerosol in the cabin. (b) The sedimentation on aeronautic equipment in the cockpit under worst-case conditions.

In the short, intermittent scenario, sedimentation was seen in the cabin and in 1 flight on the curtain but not in the cockpit. Even with doors open and wind from aft in the ground simulation, no sedimentation was observed in the cockpit.

Discussion

In the confined space of an air ambulance helicopter, massive aerosol production, simulating the conditions of a patient with an airborne transmitted disease, led to direct exposure of the medical crew and sedimentation of particles on all surfaces in the cabin and, without a barrier, on aeronautic equipment in the cockpit, too. However, a simple curtain was sufficient to prevent contamination of the cockpit. In a scenario simulating intermittent, short production of droplets (mimicking a clinical situation of coughing or disconnection of a breathing circuit in a patient with a droplet transmitted disease), the medical crew was still exposed and sedimentation accumulated around the patient but not in the cockpit. This result indicates that the amount of aerosol determines the reach and degree of contamination. Thus, the simplified concept of airborne and droplet precautions is reasonable for clinical decisions to transport a patient by air ambulance, although more complex scenarios can be used for occupational health risk assessments in general. Reference Jones and Brosseau2 Patients with an illness requiring airborne precautions should only be transported in air ambulance helicopters with a physical separation of cockpit and cabin. The curtain used for night vision goggle (NVG) flights in an H145 or H135 helicopter in our simulation seems to have been sufficient to prevent aerosols from entering the cabin. Procedural instructions for chemo-thermal washing and/or disinfection of curtains or separation walls should be developed.

Our study was limited by the model used for aerosol generation and by the number and duration of flights. Although we were able to simulate many real-life conditions on the ground and during flight, these experimental conditions clearly differ from those in commercial airplanes. Reference Sze To3 In light of recent findings about virus shedding in exhaled breath, Reference Leung, Chu and Shiu4 it seems unlikely that those aerosols would reach the cockpit just from intermittent coughing or exhalation. This risk could be further reduced if the patient wears a mask, which is recommended as part of droplet precautions. Personal protective equipment is required for the medical crew. Also, thorough cleaning of all surfaces is necessary in the cabin after transport because the contamination risk seems to be much higher in the confined helicopter cabin space compared to a normal hospital room where contamination is frequently found during routine care. Reference Phan, Sweeney and Maita5

Acknowledgments

Financial support

This work was funded by institutional funds only.

Conflicts of interest

S.S.S. is shareholder of BZH-Beteiligungs-GbR and receives royalties from Springer, Thieme, and Kohlhammer.

References

Schulz-Stübner, S, Kosa, R, Henker, J, Mattner, F, Wendel, AF. Is UV-C “light wand” mobile disinfection in air ambulance helicopters effective? Infect Control Hosp Epidemiol 2019;40:13231331.CrossRefGoogle ScholarPubMed
Jones, RM, Brosseau, LM. Aerosol transmission of infectious disease. J Occup Environ Med 2015;57:501508.CrossRefGoogle ScholarPubMed
Sze To, GN,Wan, MP Chao CYH, Fang L, Melikov A. Experimental study of dispersion and deposition of expiratory aerosols in aircraft cabins and impact on infectious disease transmission. Aerosol Sci Technol 2009;43:466485.CrossRefGoogle Scholar
Leung, NHL, Chu, DKW, Shiu, EYC, et al. Respiratory virus shedding in exhaled breath and efficacy of face masks. Nat Med 2020 Apr 3 [Epub ahead of print]. doi: 10.1038/s41591-020-0843-2.Google ScholarPubMed
Phan, LT, Sweeney, DM, Maita, DM et al. Respiratory virus in the patient environment. Infect Control Hosp Epidemiol 2020;41:259266.CrossRefGoogle ScholarPubMed
Figure 0

Fig. 1. (a) The setup to visualize the stream of marked aerosol in the cabin. (b) The sedimentation on aeronautic equipment in the cockpit under worst-case conditions.