Hostname: page-component-586b7cd67f-rdxmf Total loading time: 0 Render date: 2024-11-30T19:38:42.436Z Has data issue: false hasContentIssue false

Microsystems for Chemical and Biological Applications

Published online by Cambridge University Press:  31 January 2011

Get access

Extract

Over the past decade, there has been an explosive growth in efforts directed at developing and utilizing an array of novel microsystems in important applications in chemistry and biology. In parallel, the commercial potential of these applications has fueled the creation of hundreds of new companies and the expansion of research and development efforts at established commercial organizations. In this article, we outline the spectrum of applications of these systems and highlight some of the materials and fabrication challenges that they present.

Type
Research Article
Copyright
Copyright © Materials Research Society 2001

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

1Manz, A. and Becker, H. eds., Microsystem Technology in Chemistry and Life Sciences (Springer, New York, 1999).Google Scholar
2Urban, G.A. and Jobst, G. in Microsystem Technology in Chemistry and Life Sciences, edited by Manz, A. and Becker, H. (Springer, New York, 1999) p.189.Google Scholar
3Ivnitski, D.Abdel-Hamid, I., Atanasov, P. and Wilkins, E.Biosens. Bioelectron. 14 (1999) p. 599.CrossRefGoogle Scholar
4Gau, J.J., Lan, E.H., Dunn, B. and Ho, C.M., in Micro Total Analysis Systems 2000, edited by Berg, A. Van Den, Olthuis, W. and Bergveld, P. (Kluwer Academic Publishers, Boston, 2000) p.509.CrossRefGoogle Scholar
5Fang, M.Vatelino, K.Rothery, M.Himes, J. and Frye, G.C., Sens. Actuators B 56 (1999) p.155.CrossRefGoogle Scholar
6Manz, A.Graber, N. and Widmer, H.M., Sens. Actuators B 1 (1990) p.244.CrossRefGoogle Scholar
7Harrison, D.J., Wang, C.Thibeault, P.Ouchen, F. and Cheng, S.B., in Micro Total Analysis Systems 2000, edited by Berg, A. Van Den, Olthuis, W. and Bergveld, P. (Kluwer Academic Publishers, Boston, 2000) p.195.CrossRefGoogle Scholar
8Sanders, G.H.W. and Manz, A.Trends Anal. Chem. 19 (2000) p.364.CrossRefGoogle Scholar
9Schena, M. ed., Microarray Biochip Technology (Eaton, Natick, MA, 2000).Google Scholar
10Hamadeh, H. and Afshri, C.A., Am. Sci. 88 (2000) p.508.CrossRefGoogle Scholar
11Zhou, Y.X., Kalosai, P., Chen, J.Y., and Shams, S. in Microarray Biochip Technology, edited by Schena, M. (Eaton, Natick, MA, 2000) p. 167.Google Scholar
12Anderson, R.C., McGall, G. and Lipshutz, R.J., in Microsystem Technology in Chemistry and Life Sciences, edited by Manz, A. and Becker, H. (Springer, New York, 1999) p.117.Google Scholar
13Kutter, J P.Trends Anal. Chem. 19 (2000) p.352.CrossRefGoogle Scholar
14Effenhausser, C.S., in Microsystem Technology in Chemistry and Life Sciences, edited by Manz, A. and Becker, H. (Springer, New York, 1999) p.51.Google Scholar
15Paul, P.H., Arnold, D.W., Neyer, D.W., and Smith, K.B., in Micro Total Analysis Systems 2000, edited by Berg, A. Van Den, Olthuis, W. and Bergveld, P. (Kluwer Academic Publishers, Boston, 2000) p.583.CrossRefGoogle Scholar
16Harrison, D.J. and Berg, A. Van Den, eds., Micro Total Analysis Systems '98 (Kluwer Academic Publishers, Boston, 1998).CrossRefGoogle Scholar
17Berg, A. Van Den, Olthuis, W. and Bergveld, P. eds., Micro Total Analysis Systems 2000 (Kluwer Academic Publishers, Boston, 2000).CrossRefGoogle Scholar
18Culbertson, C.T., Jacobson, S.C., and Ramsey, J.M., in Micro Total Analysis Systems 2000, edited by Berg, A. Van Den, Olthuis, W. and Bergveld, P. (Kluwer Academic Publishers, Boston, 2000) p.221.CrossRefGoogle Scholar
19Shi, Y.Simpson, P.C., Scherer, J.R., Wexler, D.Skibola, C.Smith, M.T., and Mathies, R.A., Anal. Chem. 71 (1999) p.5354.CrossRefGoogle Scholar
20Frye-Mason, G., Kottenstette, R.Lewis, P.Heller, E.Manginell, R.Adkins, D.Dulleck, G.Martinez, D.Saaki, D.Mowry, C.Matzke, C. and Anderson, L. in Micro Total Analysis Systems 2000, edited by Berg, A. Van Den, Olthuis, W. and Bergveld, P. (Kluwer Academic Publishers, Boston, 2000) p.229.CrossRefGoogle Scholar
21Ehrfeld, W.Hessel, V. and Lehr, H. in Micro-system Technology in Chemistry and Life Sciences, edited by Manz, A. and Becker, H. (Springer, New York, 1999) p.233.Google Scholar
22Haswell, S.J. and Skelton, V.Trends Anal. Chem. 19 (2000) p.389.CrossRefGoogle Scholar
23Ramsey, J.M., Jacobson, S.C., Culbertson, C.T., and Ramsey, R.S., in Micro Total Analysis Systems 2000, edited by Berg, A. Van Den, Olthuis, W. and Bergveld, P. (Kluwer Academic Publishers, Boston, 2000) p.213.CrossRefGoogle Scholar
24Kopp, M.U., Luechinger, M.B., and Manz, A. in Micro Total Analysis Systems '98, edited by Harrison, D.J. and Berg, A. Van Den (Kluwer Academic Publishers, Boston, 1998) p.7.CrossRefGoogle Scholar
25McBride, S.E., Moroney, R.M., and Chiang, W. in Micro Total Analysis Systems '98, edited by Harrison, D.J. and Berg, A. Van Den (Kluwer Academic Publishers, Boston, 1998) p.45.CrossRefGoogle Scholar
26Qin, D.Xia, Y.Rogers, J.A., Jackman, R.J., Zhao, X.M., and Whitesides, G.M., in Micro-system Technology in Chemistry and Life Sciences, edited by Manz, A. and Becker, H. (Springer, New York, 1999) p.1.Google Scholar
27McCreedy, T.Trends Anal. Chem. 19 (2000) p.396.CrossRefGoogle Scholar
28Shoji, S. in Microsystem Technology in Chemistry and Life Sciences, edited by Manz, A. and Becker, H. (Springer, New York, 1999) p.163.Google Scholar
29Singh, A.K., Flounders, A.W., Volponi, J.V., Ashley, C.S., Wally, K. and Schoeniger, J.S., Biosens. Bioelectron. 14 (1999) p.703.CrossRefGoogle Scholar