Core share and HTML view are not available for this content. However, as you have access to this content, a full PDF is available via the ‘Save PDF’ action button.

Post-fixing with osmium tetroxide before silver-staining sections causes problems because the OsCU can etch the deposited silver. However, it is not a good idea to perform silver enhancement after osmium tetroxide treatment because the deposited osmium can also act as a nucleating site for silver deposition, and the osmicated regions of the sample will be silver enhanced. If gold-toning is used after OsO4 post-fixation, the OSO4 can also nucleate gold particles. OsO4 should always come after silver enhancement.

Type
Research Article
Copyright
Copyright © Microscopy Society of America 1999

References

1) Burry, R.W. Pre-embedding immunocytocrtemistry with silverenhanced small gold particles. Chap. 14, pp. 217230. In Hayat, M. A. ed. 1995. Immunogold silver staining: Principles, methods and applications. CRC Press, Boca Raton.Google Scholar
2) Arai, R., et at. Brain Res. Bull., 1992, 28, 343345.Google Scholar
3) Arai, R., and Nagatsu, I. 1995. in: Immunogold-Silver Staining: principles, Methods and Applications. Hayat, M. A., ed. Chap. 13, pp 209216. CRC Press, Boca Raton. FL).Google Scholar
4) Sawada, H., and Esaki, J. 1994. Elect. Micro., 43, 361–66.Google Scholar