Hostname: page-component-586b7cd67f-rcrh6 Total loading time: 0 Render date: 2024-12-01T11:53:02.557Z Has data issue: false hasContentIssue false

Single Molecule Force Spectroscopy Maps to Study Receptors Clustering

Published online by Cambridge University Press:  02 July 2020

R. Bhatia
Affiliation:
Neuroscience Research Institute, University of California, Santa Barbara, CA, 93106
N. Almqvist
Affiliation:
Department of Physics, Luleå University of Technology, SE-971 87, Luleå, Sweden
S. Banerjee
Affiliation:
Neuroscience Research Institute, University of California, Santa Barbara, CA, 93106
G. Primbs
Affiliation:
Neuroscience Research Institute, University of California, Santa Barbara, CA, 93106
N. Desai
Affiliation:
Neuroscience Research Institute, University of California, Santa Barbara, CA, 93106
R. Lai
Affiliation:
Neuroscience Research Institute, University of California, Santa Barbara, CA, 93106
Get access

Abstract

An atomic force microscope (AFM) allows molecular resolution imaging of hydrated specimens. However, it is often limited in providing identity of the imaged structures, especially in a complex system such as a cellular membrane. Cell surface macromolecules such as ion channels and receptors serve as the interface between the cytoplasm and the extracellular region and toward which many regulatory signals are directed. Their density, distribution and clustering are key spatial features influencing effective and proper physiological responses. We used a method that uses AFM “force-volume maps” to identify and map regional distribution as well as ligand-, or antibody-induced real-time clustering of receptors on the cell surface. This technique also allows simultaneous imaging of the resultant changes in cellular micromechanical properties, such as elasticity and cytoskeletal reorganization of the cell. As an appropriate physiological sample, we have examined spatial distribution and real-time clustering of VEGFR, the receptor for vascular endothelial growth factor which is an important angiogenic factor in human and animal tissues.

We have used AFM probes conjugated with anti-VEGFR-antibody (anti-Flk-1 antibody) to examine binding (or unbinding) forces between VEGF-R2 (Flk-1) in both in vitro as well as in live endothelial cells. A quantal set of binding and unbinding forces was measured between the antibody conjugated to the AFM tip and purified VEGFRs adsorbed on to a mica surface (Fig 1). The unbinding force varied between 60 and 240 pN and was a multiple of discrete quantized strength of approximately 60 pN (Figure 1B).

Type
Can Scanning Probe Microscopes Do Microanalysis? (Organized by I. Holl Musselman)
Copyright
Copyright © Microscopy Society of America 2001

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

Footnotes

Acknowledgement: Supported by NSF nanotechnology initiative and NIH (GM-NIA).