Hostname: page-component-cd9895bd7-p9bg8 Total loading time: 0 Render date: 2024-12-26T19:00:29.170Z Has data issue: false hasContentIssue false

The Potential of Cryo-Electron Tomography as Assessed by Reconstruction of Sea Urchin Axonemes

Published online by Cambridge University Press:  02 July 2020

B.F. McEwen
Affiliation:
Div. Molecular Medicine, Wadsworth Center, NYS Dept. Health, Albany, NY12201-0509. Dept. Biomedical Medical Sciences, State University of New York, Albany, NY12222.
M. Marko
Affiliation:
Div. Molecular Medicine, Wadsworth Center, NYS Dept. Health, Albany, NY12201-0509.
C-E. Hsieh
Affiliation:
Div. Molecular Medicine, Wadsworth Center, NYS Dept. Health, Albany, NY12201-0509.
J. Frank
Affiliation:
Dept. Biomedical Medical Sciences, State University of New York, Albany, NY12222. Howard Hughes Medical Institute, Wadsworth Center, NYS DOH, Albany, NY12201-0509.
Get access

Extract

Recent improvements in digital image acquisition, and automated TEM, have lowered the electron dose requirement for collecting a tomographic tilt series to the point where cryo-electron tomography is now feasible. Theoretical calculations indicate that resolution values of 2-5 nm can be obtained for fully hydrated specimens 100-500 nm thick. This resolution is sufficient for identifying individual macromolecules, and macromolecular assemblies, within-organelles and small cells. However, initial applications to cells and organelles fell short of theoretical resolution limits, indicating further development is necessary before cryo-electron tomography reaches its full potential for characterizing macromolecules in situ. Axonemes are ideal test specimens for cryo-tomography because of their appropriate size (diameter of 250 nm), ease of isolation, and unique construction from regular arrays of well-characterized components. The latter include microtubules, radial spokes, central sheath components, outer dynein arm, inner dynein arms, and the microtubule subunit lattice. These components are convenient benchmarks for evaluating the actual detection limit of tomographic reconstructions within a resolution range of 3-30 nm. Furthermore, axoneme components are sufficiently well ordered that computed diffraction patterns contain layer-lines that are useful for judging the quality of individual 2D images.

Type
Cryotechniques, Immunocytochemistry, and Electron Microscopy I. Molecular Approach
Copyright
Copyright © Microscopy Society of America

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

1. Koster, A.J.et al., J. Structural Biol. 120(1998) 276.CrossRefGoogle Scholar

2. Grimm, R.et al., Biophysical Journal 74(1998) 1031.CrossRefGoogle Scholar

3. Kenney, J.et al., J. Structural Biol. 120(1998) 320.CrossRefGoogle Scholar

4. Mannella, C.A.et al., These Proceedings.Google Scholar

5. Murray, J.M., J. Ultrastruct. Mol. Struct. Res. 95(1986) 196.CrossRefGoogle Scholar

6. McEwen, B.F.et al., Electron Microscopy 1998, (Proceed. 14th 1CEM) IV (1998) 459.Google Scholar

7. Marko, M.et al., These Proceedings.Google Scholar

8. Supported by NIH NCPP/BTP grant P41-RR01219.Google Scholar