Physical Considerations in Low Energy Biological Analysis

Published online by Cambridge University Press:  02 July 2020

David C Joy*
Affiliation:
EM Facility, University of Tennessee, Knoxville, TN37996-0810 and, Oak Ridge National Laboratory, Oak Ridge, TN37831-6064
Get access

Extract

Biological scanning electron microscopy is increasingly performed at low beam energies in order to improve image contrast, reduce charging artifacts, and minimize beam induced damage to the sample. It is natural then to wish to also use these same low accelerating voltage for X-ray microanalysis using an energy dispersive spectrometer (EDS) but a variety of fundamental physical effects affect the performance that can be achieved. An X-ray photon can only be emitted when the incident beam Eo energy exceeds the critical excitation energy Ecrit for that line. As the beam energy is reduced the number of elements that can be excited falls and it is becomes necessary to use L- and M-lines rather than the K-lines accessible at higher energies. At 5keV, the upper limit of ‘low voltage’ microscopy, K-lines can be excited from elements up to calcium, L-lines can be detected up to cesium, and the rest of the periodic table is available using M-lines. The entire periodic table is therefore, in principle, available at an overvoltage U>2, where U = E0/Ecrit But at lower energies the number of accessible excitations falls and some elements cannot, with current technology, then be analyzed and for general purposes an incident energy lower than about 3keV is probably too limiting to be useful.

Type
Low Voltage (1-5 kv) X-ray Microanalysis
Copyright
Copyright © Microscopy Society of America

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

references

(1)Joy, D C and Pawley, J B, Ultramicroscopy 47, (1992), 80CrossRefGoogle Scholar
(2)Joy, D C, J. of Microscopy, 191, 74, (1998)CrossRefGoogle Scholar
(3)Wollman, D Aet alJ.Micros., 188, 196, (1998)CrossRefGoogle Scholar
(4) Research sponsored by the Assistant Secretary for Energy Efficiency and Renewable Energy, Office of Transportation Technologies, as part of the High Temperature Materials Laboratory User program. Oak Ridge National Laboratory, managed by Lockheed Martin Energy Research Corp. for the U.S. Department of Energy under contract number DE-AC05-96OR22464.Google Scholar