Time Dependent Study of the Positive ion Current in the Environmental Scanning Electron Microscope (ESEM)

Published online by Cambridge University Press:  02 July 2020

S.W. Morgan
Affiliation:
Microstructural Analysis Unit, University of Technology, Sydney, PO Box 123, Broadway, New South Wales, Australia2007
M.R. Phillips
Affiliation:
Microstructural Analysis Unit, University of Technology, Sydney, PO Box 123, Broadway, New South Wales, Australia2007
Get access

Abstract

The Environmental Scanning Electron Microscope (ESEM) is capable of image generation in a gaseous environment at sample chamber pressures of up to 20 torr. in an ESEM, low energy secondary electrons emitted from a sample surface, by virtue of the primary electron beam, are accelerated towards the positively biased metallic ring (typically +30 to +550V) Gaseous Secondary Electron Detector (GSED). As these electrons accelerate towards the ring they undergo ionizing collisions with gas molecules producing positive ions and additional electrons known as environmental secondary electrons. The environmental electrons further ionize the gas on their way to the ring producing a cascade amplification of the original signal. The amplified signal induced in the ring is used to form an image. The electric field generated between the GSED ring and the grounded stage causes the positive ions produced in the cascade to drift towards the sample, effectively neutralizing negative charge build up on the surface of a non-conducting sample.

Type
Technologists’ Forum: ESEM/Lv/Vp: Imaging at Low Vacuum (Organized by J. Killius)
Copyright
Copyright © Microscopy Society of America 2001

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

1.Danalatos, G.D., Adv.Elec.Electron phys,71(1988)109CrossRefGoogle Scholar
2.Moncrieff, D.A. et al., J.Phys.D:Appl.Phys, 11(1978)2315CrossRefGoogle Scholar
3.Toth, M. and Phillips, M.R., Scanning, 22(2000)319CrossRefGoogle ScholarPubMed
4.von Engel, A., Ionized Gases, Clarendon Press, Oxford (1965)CrossRefGoogle Scholar
5.Craven, J.P. et al., Microscopy and Microanalysis(S2), (2000)776CrossRefGoogle Scholar
6.Fletcher, A.L. et al., J.Phys.D:Appl.Phys, 30(1997)2249CrossRefGoogle Scholar
7.Merideth, P. et al., Scanning, 18(1996)467CrossRefGoogle Scholar