Mapping the Subcellular Distribution of Calcium in Depolarized Neurons by Electron Energy Loss Spectrum Imaging

Published online by Cambridge University Press:  02 July 2020

S.B. Andrews
Affiliation:
laboratory of Neurobiology, NINDS, and, Div. Bioengineering & Physical Science, ORS, NIH, Bethesda, MD20892
J. Hongpaisan
Affiliation:
laboratory of Neurobiology, NINDS, and, Div. Bioengineering & Physical Science, ORS, NIH, Bethesda, MD20892
N.B. Pivovarova
Affiliation:
laboratory of Neurobiology, NINDS, and, Div. Bioengineering & Physical Science, ORS, NIH, Bethesda, MD20892
D.D. Friel
Affiliation:
Dept. Neuroscience, Case Western Reserve, Cleveland, OH44106.
R.D. Leapman
Affiliation:
Div. Bioengineering & Physical Science, ORS, NIH, Bethesda, MD20892
Get access

Extract

In the context of biological specimens, it is in principle desirable to quantitatively map, rather than just point analyze, the distribution of physiologically important elements, and to do so at subcellular resolution. Presently, this can be accomplished by electron energy loss spectrum-imaging (EELSI) in both the scanning transmission electron microscope (STEM) and the energy-filtering transmission electron microscope (EFTEM). Until recently, this approach has been of limited value for mapping the particularly important element Ca, mainly because intracellular total Ca concentrations are normally quite low (<5 mmol/kg dry weight) and because the background in the vicinity of the Ca L23 edge is complex and requires precise background modeling to extract the very weak Ca signals. As a result, the Ca signal is usually not high enough to reach detection threshold during a practical EELSI acquisition time.

Type
Electron Energy-Loss Spectroscopy (EELS) and Imaging
Copyright
Copyright © Microscopy Society of America

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

1.Hunt, J. & Williams, D.B., Ultramicroscopy 38 (1991) 47.CrossRefGoogle Scholar
2.Jeanguillaume, C. & Colliex, C., Ultramicroscopy 28 (1989) 252.CrossRefGoogle Scholar
3.Shuman, H. et al., Ann NY Acad Sci 483 (1986) 295.CrossRefGoogle Scholar
4.Lavergne, J.L. et al., Microsc Microanal Microstruct 3 (1992) 517.CrossRefGoogle Scholar
5.Hunt, J.A. et al., Microsc. & Microanal. 5 (Suppl. 2) (1999) 616.CrossRefGoogle Scholar
6.Pivovarova, N. et al., J. Neurosci 19 (1999) 6372.CrossRefGoogle Scholar
7.Leapman, R.D. & Hunt, J.A., J Electron Microsc Soc Am 1 (1995) 93.Google Scholar
8.Andrews, S.B.. et al., Scanning Microscopy (Suppl) (1999), in press.Google Scholar
9.Friel, D.D. & Tsien, R.W., J Physiol (Lond) 450 (1992) 217.CrossRefGoogle Scholar
10. The authors thank Dr. Hunt, J.A. (Gatan) for beta versions of the spectrum-imaging software. Supported in part by Grant No. 96077490 from the American Heart Association (DDF).Google Scholar