High Spatial Resolution Low Energy Electron Beam X-ray Microanalysis

Published online by Cambridge University Press:  02 July 2020

I.R. Barkshire
Affiliation:
Oxford Instruments Microanalysis Group, Halifax Rd, High Wycombe, Bucks, HP 12 3SE, UK
P. Karduck
Affiliation:
RWTH, Aachen University of Technology, GFE Central Facility for Electron Microscopy, Ahornstrasse 55, D-52074, Aachen, Germany
W. Rehbach
Affiliation:
RWTH, Aachen University of Technology, GFE Central Facility for Electron Microscopy, Ahornstrasse 55, D-52074, Aachen, Germany
S. Richter
Affiliation:
RWTH, Aachen University of Technology, GFE Central Facility for Electron Microscopy, Ahornstrasse 55, D-52074, Aachen, Germany
Get access

Extract

Conventionally, x-ray microanalysis on scanning electron microscopes (SEM) with energy dispersive spectrometers (EDS) has been performed with relatively high primary energies (>10 kv). for most samples this results in reasonably good separation of the generated x-ray line series from different elements enabling unambiguous identification and therefore accurate qualitative analysis. Under these circumstances it is widely accepted that quantitative analysis of polished bulk samples is possible on a routine basis with relative errors around 1-5% and detection limits of the order of 0.1%.

However, in order to address the analysis requirements of new advanced materials with sub-micron features, there is growing interest in performing x-ray microanalysis at low beam energies(<5kv). this is now a more realistic goal due to the routine availability of field emission sem's which can operate with much improved beam sizes at low beam energies with sufficient beam current to perform practical microanalysis, in conjunction with the improved low energy performance of current, commercially available EDS systems.

Type
Low Voltage (1-5 kv) X-ray Microanalysis
Copyright
Copyright © Microscopy Society of America

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

references

1.Reed, S.J.B.. Electron Microprobe Analysis. Cambridge University Press l993Google Scholar
2.Nockolds, C.E.. Microbeam Analysis, 3 (1994) 185.Google Scholar
3.Boyes, E.D.. Adv. Mater. 10 (1998) 1277.3.0.CO;2-D>CrossRefGoogle Scholar
4.Willich, P. and Bethke, R.. Mikrochim. Acta [Suppl.] 13 (1996) 631Google Scholar
5.Ammann, N. and Karduck, P.. Microbeam Analysis (1990) 150Google Scholar
6.Newbury, D.. Microscopy and Microanalysis 3 (1997) 881.CrossRefGoogle Scholar
7.Statham, P.J.. X-ray Spectrometry in Electron Beam Instruments. Plenum Press, New York, 1995Google Scholar