Hostname: page-component-586b7cd67f-l7hp2 Total loading time: 0 Render date: 2024-11-29T04:41:20.765Z Has data issue: false hasContentIssue false

10 Years of Pulsed-Xenon Ultraviolet Disinfection

Published online by Cambridge University Press:  02 November 2020

Mark Stibich
Affiliation:
Xenex. Inc
Sarah Simmons
Affiliation:
Xenex Disinfection Systems
Deborah Passey
Affiliation:
Xenex Disinfection Services
Rights & Permissions [Opens in a new window]

Abstract

Core share and HTML view are not available for this content. However, as you have access to this content, a full PDF is available via the ‘Save PDF’ action button.

Background: Ultraviolet light (UV) disinfection using low-pressure mercury lamps has been around since the 1940s. The advent of pulsed-xenon UV for hospital use in 2010 has provided a nontoxic and novel technology for hospital disinfection with the first data presented at the 2010 SHEA Decennial. The purpose of this systematic review and meta-analysis is to examine the current body of evidence for pulsed xenon UV disinfection. Methods: The literature search criteria included the following: research conducted in domestic and international settings using pulsed-xenon for surface disinfection, published between 2000 and 2019, and reporting on environmental effectiveness or hospital-acquired reductions (HAIs). We searched PubMed, Google Scholar, and Web of Science. The meta-analysis included 24 studies: 12 HAI outcome studies and 12 environmental effectiveness studies. Meta-analyses were conducted by calculating the percentage reductions for environmental effectiveness, and for the HAI outcome studies, we used a random-effects model to pool the relative risk of HAI. The outcome studies used 272 and 299 months of data for the experimental and control groups, respectively. Results: There was an overall benefit of using pulsed-xenon UV. The overall relative risk of infection decreased compared to the control arm (RR, 0.64; 95% CI, 0.54–0.76). The percentage reductions in environmental studies were as follows: Clostridioides difficile (94.8%), methicillin-resistant Staphylococcus aureus(91.5%), vancomycin-resistant Enterococcus (99.2%), and aerobic bacteria (94.2%). Conclusions: Overall, pulsed-xenon UV was effective for reducing environmental contamination and had the ability to significantly reduce HAIs.

Funding: Xenex, Inc., funded this study.

Disclosures: Mark Stibich receives a salary from Xenex and is a shareholder of Xenex. Deborah Passey receives a salary from Xenex Disinfection Services.

Type
Poster Presentations
Copyright
© 2020 by The Society for Healthcare Epidemiology of America. All rights reserved.