Hostname: page-component-cd9895bd7-gxg78 Total loading time: 0 Render date: 2024-12-18T17:11:12.928Z Has data issue: false hasContentIssue false

Investigation of Three Different UV-C Irradiation Schemes for Bacterial Decontamination of FFP2 Masks to Make Them Reusable

Published online by Cambridge University Press:  29 April 2024

Franziska Vaupel
Affiliation:
Bundeswehr Central Hospital Koblenz, Department of Microbiology and Hospital Hygiene, Koblenz, Germany University Bonn, Institute for Hygiene and Public Health, Venusberg-Campus 1, Bonn, Germany
Ingo Fengler
Affiliation:
Bundeswehr Central Hospital Koblenz, Department of Microbiology and Hospital Hygiene, Koblenz, Germany
Nico T. Mutters
Affiliation:
University Bonn, Institute for Hygiene and Public Health, Venusberg-Campus 1, Bonn, Germany
Patrick Scheid
Affiliation:
Bundeswehr Central Hospital Koblenz, Department of Microbiology and Hospital Hygiene, Koblenz, Germany
Esther Sib
Affiliation:
University Bonn, Institute for Hygiene and Public Health, Venusberg-Campus 1, Bonn, Germany
Ruth Weppler
Affiliation:
Bundeswehr Central Hospital Koblenz, Department of Microbiology and Hospital Hygiene, Koblenz, Germany
Manuel Döhla*
Affiliation:
Bundeswehr Central Hospital Koblenz, Department of Microbiology and Hospital Hygiene, Koblenz, Germany University Bonn, Institute for Hygiene and Public Health, Venusberg-Campus 1, Bonn, Germany
*
Corresponding author: Manuel Döhla; Email: [email protected].
Rights & Permissions [Opens in a new window]

Abstract

The effect of filtering face piece grade 2 (FFP2) masks for infection prevention is essential in health care systems; however, it depends on supply chains. Efficient methods to reprocess FFP2 masks may be needed in disasters. Therefore, different UV-C irradiation schemes for bacterial decontamination of used FFP2 masks were investigated.

Seventy-eight masks were irradiated with UV light for durations between 3 and 120 seconds and subsequently analyzed for the presence of viable bacteria on the inside. Ten masks served as the control group. Irradiation on the inside of the masks reduced bacteria in proportion to the dose, with an almost complete decontamination after 30 seconds. Outside irradiation reduced the quantity of colonies without time-dependent effects. Both sides of irradiation for a cumulated 30 seconds or more showed almost complete decontamination.

Overall, this study suggests that standardized UV irradiation schemes with treatment to both sides might be an efficient and effective method for FFP2 mask decontamination in times of insufficient supplies.

Type
Concepts in Disaster Medicine
Creative Commons
Creative Common License - CCCreative Common License - BY
This is an Open Access article, distributed under the terms of the Creative Commons Attribution licence (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted re-use, distribution and reproduction, provided the original article is properly cited.
Copyright
© The Author(s), 2024. Published by Cambridge University Press on behalf of Society for Disaster Medicine and Public Health, Inc

Filtering face piece (FFP) masks are an essential part of personal protective equipment (PPE) for the transmission prevention of air transmitted bacteria or viruses both in the medical and public sectors. Increased demand leads to increased dependence on supply chains. Reference Bhaskar, Tan and Bogers1 Therefore, disruption in production, shipment, or delivery may result in mask shortages with severe consequences for individual health and public health. Incidences like the coronavirus pandemic in 2019, 2 the accident of the “Ever Given,” Reference Özkanlisoy and Akkartal3 the war in Ukraine, Reference Dyson, Helbig and Avermaete4 and the earthquakes in Turkey and Syria in 2023 5 clearly demonstrated the fragility of this supply chain system. Especially, mask shortages during the coronavirus disease (COVID-19) pandemic emphasized the importance of the supply-chain-independent provision of FFP2 masks. In March 2020, the World Health Organization (WHO) warned of danger to health care workers due to shortages of personal protective equipment such as FFP2 masks 2 while patients with COVID-19 had to be treated by doctors and nursing staff without masks. Reference Nocchi and Giorgi6 It must be assumed that globalization and climate change will make pandemic Reference de Oliveira and Tegally7 and supply chain disruptions more common, due to maritime events, for example. Reference Er Kara, Ghadge and Bititci8 This makes it impossible to guarantee a constant and sufficient supply of masks through shipment and delivery.

In order to decrease the dependency on supply chains and be better prepared in the event of a crisis or disaster, it is expedient to develop reprocessing concepts for FFP2 masks and to examine their effectiveness. In recent years, various reprocessing methods have been investigated and resulting recommendations were published. 9Reference Blacky, Buchrieser and Freundlinger11 These included reprocessing via moist and dry heat, gaseous hydrogen peroxide, and steam. Reference Peters, Lotfinejad and Palomo12 The use of ultraviolet (UV) irradiation (especially UV-C) led to ambiguous results in the past. Reference Peters, Lotfinejad and Palomo12

UV irradiation has been used for many years for the disinfection of water, surfaces, and air. Reference Vasilyak13 The absorption of UV irradiation induces stable connections between 2 pyrimidine bases in the deoxyribonucleic acid (DNA) of microorganisms such as bacteria, leading to the formation of especially thymine dimers and causing the disruption of the DNA’s replication. The microorganism becomes incapable of reproduction or dies. Reference Kraft, Obst and Schwartz14 The UV lamps used in this study emitted UV-C light, which is the most energetic part of UV light. It ranges at wavelengths from 100 nm to 280 nm 15 and includes the absorption maximum of nucleic acids at 260 nm. Reference Kraft, Obst and Schwartz14

In this study, effective UV-C irradiation schemes for bacterial decontamination of FFP2 masks were investigated with the aim of reusing worn masks in times of insufficient supplies.

Methods

Acquisition of Used Masks

All masks examined had been worn properly by hospital staff (according to the severe acute respiratory syndrome coronavirus 2 [SARS-CoV-2] pandemic regulations) and were collected randomly throughout the hospital personnel. The mask users were informed verbally about the planned examinations. No personal data were collected, and only the duration of use was documented. Participation was voluntary, and handing over the mask was therefore considered informed consent. Only masks with a duration of use between 1 and 12 hours, that were visually intact and clean, were included in this study. The chosen masks were subsequently packed in sealable plastic bags and transported to the laboratory within a maximum of 8 hours after use. The distribution of the masks among the different UV-C irradiation schemes was also random.

Irradiation

The study used the irradiation chamber BS-02 with the control unit UV-Mat (Opystec Dr Gröbel GmbH, Ettlingen, Germany). It was equipped with 8 UV-C lamps (Philips, TUV 15W G15 T8, Hamburg, Germany). The luminants emitted radiation with a wavelength of approximately 250 nm. 16 The distance between the masks and the UV-C lamps was 15 cm.

The irradiation chamber ran on full power with 10 ${{mW} \over {c{m^2}}}$ 17 since no dimming was set. Two masks were irradiated simultaneously per run (Figure 1) with an estimated average energy throughput of 95%. The formula for the calculation of the irradiation dose is shown in Equation 1.

(1) $$\scriptsize {Irradiatn{\rm{\;}}dose{\rm{\;}}per{\rm{\;}}side{\rm{\;}}\left[ {{{mJ} \over {c{m^2}}}} \right] \!=95{\rm{\% \,*}}\,10{{mW} \over {c{m^2}}}\,{\rm{*}}\,duration{\rm{\;}}of{\rm{\;}}irradiation}$$

Figure 1. Schematic top-down view of the irradiation chamber with decreases of irradiation efficiency in the different areas. 16 The door of the chamber is on the bottom of the figure. The masks are figured in white; the metallic mask holders are figured in transparent white.

The UV-C irradiation schemes were

  1. 1. Inside irradiation only; masks face-side up in the chamber

  2. 2. Outside irradiation only; masks face-side down in the chamber

  3. 3. Both sides of irradiation, combined; masks face-side up in the chamber and rotated after half the irradiation time

Bacterial Examination

All masks were examined according to Deutsches Institut für Normung e.V. (DIN) 10113 18 using 25 cm2 Tryptic Soy Agar plates (RODAC contact plates, Becton Dickson, New Jersey, USA). The incubation period was 48 hours at 37±2 °C. All bacteria that were identified as potentially clinically relevant based on their morphology were sub-cultivated on Columbia Agar (with 5% Sheep Blood, Becton Dickson, New Jersey, USA) and further characterized via Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS, MALDI Biotyper, Bruker Daltonics GmbH & Co. KG, Bremen, Germany).

Statistical Analysis

Stata IC 15.1 (StataCorp, College Station, Texas, USA) was used for statistical analysis. The study focused on non-parametric methods for the statistical analysis of the data, as a normal distribution could not be assumed due to the small sample size. The alpha-level was set at 0.05.

The influence of the duration of mask use on bacterial contamination in non-irradiated masks was tested via a linear regression. For irradiated masks, a linear regression was used to test the influence of irradiation time on the bacterial contamination treatment.

The Kruskal–Wallis test was used to detect differences in duration of use or model type between and within the different UV-C irradiation schemes.

Results

Table 1 shows the number of irradiated masks by UV-C irradiation scheme with duration of use and model types. There was no global difference in the duration of use between the different UV-C irradiation schemes (P = 0.5648). Within the UV-C irradiation schemes, there was no difference in the duration of use between the various irradiation times (P inside = 0.2536, P outside = 0.1370, P both sides = 0.4944). There was no global difference in the model types between the different UV-C irradiation schemes (P = 0.4647). Within the UV-C irradiation schemes, there was no difference in the model types between the different irradiation times (P inside = 0.7228, P outside = 0.4060, P both sides all masks were identical).

Table 1. Manufacturer, model, EN149 mask type: bluebec, model BB203, FFP2NR; MUSK, MUSK21, FFP2NR; Sentias, DE.W42-A, FFP2NR; Amoedos Healthcare; DMaske, 2a, FFP2NR; Mea Vita, HKN001, FFP2NR; Guangdong YIDAO medical technology, YPHD, KN95

Figure 2 shows the boxplots of the bacterial contamination after different UV-C irradiation schemes. The median bacterial contamination of non-irradiated masks was 140.5 [interquartile range (IQR): 62–287] ${{colony\;forming\;units\;\left( {CFU} \right)} \over {25c{m^2}}}$ . The regression showed no significant influence of the duration of use on bacterial contamination in non-irradiated masks (P = 0.837, R² = 0.0056).

Figure 2. Total CFU/25cm² for the different irradiation schemes for different irradiaton durations in seconds. Red: Inside irradiation, time-dependent reduction between 3 and 30 seconds, then stable values between 30 and 120 with a maximum of 2 CFU/25cm². Blue: Outside irradiation between 30 and 120 seconds, no time-dependent reduction. Green: both sides of irradiation (inside before outside). Time-dependent reduction between 30 and 60 seconds, then stable values with a maximum of 2 CFU/25cm².

Inside Irradiation

For inside irradiated masks, the median bacterial contamination was 0 [IQR: 0–1] ${{CFU} \over {25c{m^2}}}$ . There was a time-dependent effect (P = 0.004, R² = 0.1927).

  • After 3 seconds of irradiation time (corresponding to 712.5 ${{mJ} \over {25c{m^2}}}$ ), the median bacterial contamination was 4.5 [IQR: 1.5–8.5] ${{CFU} \over {25c{m^2}}}$ .

  • After 15 seconds of irradiation time (corresponding to 3562.5 ${{mJ} \over {25c{m^2}}}$ ), the median bacterial contamination was 1.5 [IQR: 0–3.5] ${{CFU} \over {25c{m^2}}}$ .

  • After 30 seconds or more (7125 ${{mJ} \over {25c{m^2}}}$ or more), the maximum bacterial contamination was 2, medians were 0–0.5 ${{CFU} \over {25c{m^2}}}$ .

Outside Irradiation

For outside irradiated masks, the median bacterial contamination was 6 [IQR: 1–20.5] ${{CFU} \over {25c{m^2}}}$ . There were no time-dependent effects (P = 0.232, R² = 0.0782). The highest bacterial contamination remained after 120 seconds of irradiation time with median 23 [IQR: 8.5–38] ${{CFU} \over {25c{m^2}}}$ . The lowest bacterial contamination remained after 60 seconds of irradiation time with median 4 [IQR: 2–7] ${{CFU} \over {25c{m^2}}}$ .

Both Sides of Irradiation

For both sides of irradiated masks, the median bacterial contamination was 0 [IQR: 0–1.5] ${{CFU} \over {25c{m^2}}}$ . There were no time-dependent effects (P = 0.186, R² = 0.1216). After a cumulated 30 seconds (15 seconds inside, followed by 15 seconds outside) of irradiation, the median bacterial contamination was 0.5 [IQR: 0–4] ${{CFU} \over {25c{m^2}}}$ , the maximum bacterial contamination was 7 ${{CFU} \over {25c{m^2}}}$ . After a cumulated 120 seconds (60 seconds inside, followed by 60 seconds outside) of irradiation, median bacterial contamination was 0 [IQR: 0–1] ${{CFU} \over {25c{m^2}}}$ , the maximum bacterial contamination was 2 ${{CFU} \over {25c{m^2}}}$ .

Bacterial Differentiation

No obligate or facultative human pathogens were detected in any of the examined samples. Suspicious colonies were identified as bacteria of the human flora, including Kocuria rhizophila, Micrococcus sp., Neisseria perflava, Staphylococcus epidermidis, and S. saprophyticus.

Limitations

This study has 4 main limitations. First, the initial contamination of the masks before irradiation was not investigated. The irradiated masks were not bacterially examined before the intervention and therefore the concrete bacterial reduction through UV-C for each mask could not be determined. In this study, the bacterial examination of the 10 masks that served as a control group showed a high variance in bacterial quantity with a median contamination of 140.5 CFU per 25cm 2 . Another study showed similar results with a median CFU count of 168 ± 24.7 on the face-side and 36.0 ± 7.0 on the outer-side. Reference Park, Khadka and Sato19 The high variance in bacterial quantity on worn masks accentuates the importance of investigating how the initial contamination may influence the irradiation result.

Second, it remains unclear whether the reported UV-C irradiation schemes are applicable for the reprocessing of other mask types as only a representative number of FFP2 masks from the manufacturer Bluebec was included in the study (see Table 1). The irradiation results with the few masks from other manufacturers indicate a low impact of the manufacturer on the results. However, this assumption must be evaluated on a larger scale.

Third, it was not examined whether the reported UV-C irradiation schemes may reduce the filtration power of the reprocessed masks due to any adverse effects on the mask fibers. Most studies indicate that UV-C-irradiation has little or no effect on the mask’s particle penetration Reference Nicolau, Filho and Zille20 and it seems that the limiting factor for the maximum number of reprocessing cycles is the integrity of the respirator body. Reference Lindsley, Martin and Thewlis21 One study indicates that an irradiation dose of 120 ${J \over {c{m^2}}}$ could lead to significant changes in the integrity of the body material. Reference Lindsley, Martin and Thewlis21 This dose is equivalent to the irradiation dose of over 200 reprocessing cycles with the reported UV-C irradiation schemes. It can therefore be assumed that the maximum number of reprocessing cycles is limited not by the reprocessing itself but by the wear and tear of frequent mask use by health care workers. As the material integrity is very dependent on the respirator model, the impact of the reported UV-C irradiation schemes on the particle penetration should be further investigated on different respirator models and for several reprocessing cycles.

Last, only the effectiveness of irradiation on bacteria was investigated. To what extent the results can be transferred to viruses is not certain. In previous studies, the UV-C doses required for the inactivation of various viruses were investigated. The highest recommended dose required to achieve a 3-logarithmus reduction listed in a detailed compilation was 171 ${{mJ} \over {c{m^2}}}$ for John Cunningham polyomavirus. Reference Masjoudi, Mohseni and Bolton22 In the presented study, 30 seconds of irradiation translated into a dose of 285 ${{mJ} \over {c{m^2}}}$ . It can therefore be assumed that the irradiation duration that was found to be sufficient for the inactivation of bacteria is also sufficient for the inactivation of viruses. A confirmative study with the same standardized study protocols on this question seems appropriate and expedient.

Discussion

This study shows that in times of crisis or insufficient supplies, effective UV-C irradiation schemes can be used for bacterial decontamination of used FFP2 masks to efficiently make them reusable.

All reported UV-C irradiation schemes showed a reducing effect on the bacterial growth after treatment. According to DIN 10113, 18 which defines a residual contamination of 10 ${{CFU} \over {25c{m^2}}}$ as low-grade contamination, an irradiation for 3 seconds per side would be enough to decontaminate FFP2 masks sufficiently. However, because of the high variance of the CFU count at low irradiation durations and the small and unbalanced sample sizes, a contamination of 2 ${{CFU} \over {25c{m^2}}}$ or less was considered as acceptable in this study.

For outside irradiated masks, the lowest effect can be seen with a decrease in bacterial growth from 140 to 6 ${{CFU} \over {25c{m^2}}}$ . The irradiation does not sufficiently penetrate the mask to acceptably decontaminate the other side. For inside irradiation, there is a time-dependent effect, with a median bacterial growth of 0 ${{CFU} \over {25c{m^2}}}$ after at least 30 seconds of irradiation. It can be concluded that inside irradiation sufficiently decontaminates the mask on the same side after 30 seconds of irradiation. As the outside irradiation did not penetrate the mask to sufficiently decontaminate the inner side, it can be assumed that inside irradiation does not sufficiently decontaminate the outside of the mask. To effectively decontaminate FFP2 masks on both sides, both sides of irradiation seem necessary. Both sides of irradiated masks show no time-dependent differences in the bacterial growth after cumulative irradiation between 30 and 120 seconds. Furthermore, the differentiation of grown colonies on irradiated masks showed only bacteria that are part of the normal skin microbiome, Reference Kandi, Palange and Vaish23,Reference Davis and Baron24 that pose no danger to immunocompetent people. Therefore, we deduce that both sides of irradiation of 30 seconds each with a power of 10 ${{mW} \over {c{m^2}}}$ may be a suitable UV-C irradiation scheme for future use.

When comparing the data of this study with literature data, it is striking that other studies indicate a lower necessary UV-C dose for bacterial decontamination. In this study, 30 seconds of irradiation per side (corresponding to 285 ${{mJ} \over {c{m^2}}}$ per side) were sufficient to bacterially decontaminate worn masks successfully. In another study on the inactivation of various antibiotic resistant bacteria, for example, MRSA and E. coli, an irradiation dose of less than 20 ${{mJ} \over {c{m^2}}}$ led at least to a 3-log reduction of bacteria. Reference McKinney and Pruden25 One reason for the relatively high inactivation doses determined in the present study could be the different layers of the FFP2 mask that have to be penetrated by UV light for complete decontamination. Reference Nicolau, Filho and Zille20 A study by Fisher and Shaffer on the minimum UV-C dose necessary for the decontamination of filtering face piece respirators found a dose of 100 ${{mJ} \over {c{m^2}}}$ to be sufficient for at least a 3-log reduction in a viable virus. Reference Fisher and Shaffer26 This is about one-third of the minimum UV-C dose recommended in this study. A possible explanation could be the irregular surface of the masks. In this study, whole masks were used for the experiment, while Fisher and Shaffer used circular excisions from the masks. Reference Fisher and Shaffer26 It has been proven that UV light dosage varies significantly depending on the positioning of the masks and that shaded zones may require a higher UV dosage. Reference Baluja, Arines and Vilanova27

Moreover, it must be considered whether the duration of mask use or other user-dependent factors had an influence on the outcome of this study. The results show that the duration of use has only a subordinate influence on bacterial contamination before irradiation, whereas other user-dependent factors seem to have a greater influence on bacterial contamination: It has been proven that beards in different lengths or styles correlate with an increased amount of CFU found inside a mask. Reference Papale, De Palma and Amodeo28 However, due to the equally distributed median duration of use of the masks between our radiation schemes, it can be assumed that these user-dependent factors are also randomly equally distributed.

While being successful in proving the effectiveness of the presented method, statements about its efficiency, especially its practicability and its suitability for the masses, are more difficult to make. Particularly both sides of irradiation mean a lot of handling and may bear the risk of recontamination because the masks have to be rearranged between inside and outside radiation. To counteract this risk, a standard operation procedure including sufficient hand hygiene and the use of a face mask (as well as UV-C protective eyewear) by the operator is necessary. Additionally, the masks could be packed in special UV-C-permeable foils 29 that do not absorb UV-light during irradiation and therefore have no impact on the irradiation intensity. This could decrease the risk of mask recontamination while rearranging them between inside and outside irradiation or while wrapping the masks up after the completed irradiation. Further research on different package materials could be expedient.

Another factor that influences efficiency is the throughput of the method. The study design allows the simultaneous irradiation of 2 face masks in a net time of 60 seconds. Additional time is required for loading the irradiation chamber, rotating the masks and prior packaging, if necessary, as well as for personal hygiene measures and handling the protective equipment. Assuming a gross expenditure time of 150 seconds per 2 masks, the throughput would be a maximum of 48 face masks per hour per chamber with 1 staff member working continuously. This way, 1.152 masks could be reprocessed every 24 hours in times of shortages. To further enhance the method’s efficiency, it could be considered to increase the number of simultaneously irradiated face masks. The maximum number of masks that fit into the chamber is 5. To obtain the same UV-C doses, the net irradiation time would have to be increased due to the variable distribution of the radiation intensity, as shown in Figure 1. Additionally, the risk of recontamination would be increased because with 5 masks inside the chamber, the handling becomes even more difficult. There would also not be enough space to guarantee that the masks do not touch each other while being rearranged.

To conclude, the presented method is not suitable for larger amounts of face masks because of the complex handling that requires 1 staff member to work continuously and the impracticality to increase the number of simultaneously irradiated masks. It is, however, efficient and practicable for a small number of masks.

There are several promising irradiation devices other than the UV-irradiation chamber used in this study, whose practicability has been examined in other studies. Reference Weaver, McElvany and Gopalakrishnan30Reference Li, Alhmidi and Scott32 An irradiation device that is more accessible than the UV-chamber used in this study is the biosafety cabinet. It is a common element in most academic and hospital laboratories and therefore does not have to be purchased specifically for the reprocessing of masks. The downsides to the reprocessing of face masks in a biosafety cabinet are the lack of the device’s portability and the long irradiation times, even when the masks are elevated toward the UV-lamps to reach a higher irradiation dose. Reference Weaver, McElvany and Gopalakrishnan30 To reach the UV irradiation dose that was found to be sufficient for the reprocessing of worn masks in the present study, the masks would have to be irradiated for at least 20 minutes per side. Reference Weaver, McElvany and Gopalakrishnan30 Additionally, the biosafety cabinet cannot be used for its original purposes while masks are being irradiated, which could hold up other work processes. Even if this method could be used in the case of need, the method presented in this study is more locally flexible and has a higher throughput than the biosafety cabinet.

A novel device made specifically for the efficient reprocessing of used face masks is the Synchronous UV Decontamination System (SUDS). It is a device for both sides of irradiation of 1 mask at a time with a dose of over 2 ${J \over {c{m^2}}}$ in about 1 minute. Reference Kayani, Weaver and Gopalakrishnan31,Reference Li, Alhmidi and Scott32 With a reprocessing time of about 2.5 minutes for 2 masks, the throughput of the SUDS is comparable to the throughput of the method presented in this study. The small size makes the device even more portable than the UV-C chamber but restricts its possible use for other reprocessing purposes.

In summary, the UV-C irradiation chamber used for the reprocessing method investigated in this study makes it possible to reach a high throughput with a high flexibility in terms of location and type of use. The SUDS could be a promising alternative or addition to the UV irradiation chamber in the implementation of the presented method, while biosafety cabinets have a lower throughput and are less flexible in terms of location of use.

As for the use outside of crisis situations when supply chains are sufficiently intact, the presented method cannot be recommended. The single use of FFP2 masks is more hygienic than reprocessing them and, especially, this method is prone to errors due to all the handling during the work process, for which there are no process control options. Furthermore, the method should not be considered in routine settings due to the lack of product control options: As 1 batch consists of only 2 masks, it is impracticable to carry out a product control process after each irradiation treatment. Errors in the reprocessing process that could possibly lead to inadequately decontaminated masks can therefore hardly be identified. Additionally, in the European Union 33 as well as the United States of America, 34 the reprocessing of disposable products is associated with the assumption of producer responsibility. The reprocessor must prove that the functionality and product safety are guaranteed. Full evidence for this guarantee is not given by this work.

Nonetheless, the presented UV-C decontamination method could be an option for the decontamination of face masks in times of crisis or disaster. The irradiation chamber is very portable and can therefore be used flexibly locally: It is transportable by 2 people or by truck or aircraft and needs only electricity and no other resources, compared to reprocessing using steam, for example. It could therefore be of use for mobile medical units or small medical facilities. The method may improve hygiene and prevent infections whenever supply chains are disrupted, for example, in epidemic or pandemic situations, in remote areas with no supply, or during military operations. It can be especially advantageous during disasters like flooding or earthquakes: Areas where an earthquake occurred are often difficult to reach, medical facilities are not accessible, and resources are needed spontaneously and quickly. 35,Reference Zhang, Liu and Li36 Additionally, natural disasters like earthquakes often have outbreaks of infectious diseases as a consequence, for example, due to overcrowded shelters or limited hygiene. Reference Kouadio, Aljunid and Kamigaki37 The presented method to make FFP2 masks reusable efficiently could improve the medical conditions in these areas.

The situations in which the presented method could be of use are highly variable as well as unpredictable. To be better prepared for supply chain disruptions and other possible consequences of disasters, it is recommended to create a generally accessible list of where the necessary resources for this method, such as UV-C irradiation chambers, are located. This way, the resources could be quickly transported to wherever needed in the surrounding area. This could be especially advantageous, and it is believed that pandemics and natural disasters will become more common in the future due to climate change and globalization. Reference de Oliveira and Tegally7,Reference Er Kara, Ghadge and Bititci8

Conclusion

UV-C irradiation for 30 seconds inside, followed by 30 seconds outside (translating into 7125 ${{mJ} \over {25c{m^2}}}$ per side), is an efficient UV-C irradiation scheme for bacterial decontamination of FFP2 masks to make them reusable. This reprocessing method can be used as a last resort when no new masks are otherwise available because of supply chain disruptions, disasters, or pandemics, for example. It could be advantageous to create a generally accessible list of where the necessary resources are located.

Author contributions

FV carried out the irradiation, prepared the microbiological samples, and wrote the first draft of the manuscript. IF evaluated the microbiological samples and revised the manuscript. NTM planned and supervised the investigations and revised the manuscript. PS provided resources (irradiation chamber, staff for briefing). ES evaluated the microbiological samples. RW provided resources (masks) and created the database and supervised the documentation of the examinations. MD planned and supervised the investigations, analyzed the data, and revised the manuscript.

Funding statement

None.

Competing interests

All authors state that they have no competing interests regarding this study.

Ethical standards

No personal data were collected, processed, or saved for this study. No experiments were conducted on or with humans or animals. The irradiated masks are legally considered waste, which means that there are no longer any property rights. Therefore, IRB approval was not necessary from the authors’ points of view.

References

Bhaskar, S, Tan, J, Bogers, MLAM, et al. At the epicenter of COVID-19–the tragic failure of the global supply chain for medical supplies. Front Public Health. 2020;8:562882. doi: 10.3389/fpubh.2020.562882 CrossRefGoogle ScholarPubMed
Shortage of Personal Protective Equipment Endangering Health Workers Worldwide. World Health Organization. Published March 3, 2020. Accessed March 11, 2023. https://www.who.int/news/item/03-03-2020-shortage-of-personal-protective-equipment-endangering-health-workers-worldwide Google Scholar
Özkanlisoy, Ö, Akkartal, E. The effect of Suez Canal blockage on supply chains. Dokuz Eylül Üniversitesi Denizcilik Fakültesi Derg. 2022;14(1):51-79. doi: 10.18613/deudfd.933816 CrossRefGoogle Scholar
Dyson, E, Helbig, R, Avermaete, T, et al. Impacts of the Ukraine–Russia conflict on the global food supply chain and building future resilience. EuroChoices. 2023;22(1):14-19. doi: 10.1111/1746-692X.12380 CrossRefGoogle Scholar
WHO Sends Health Supplies to Reach 400 000 People Impacted by the Earthquakes in Türkiye and the Syrian Arab Republic. World Health Organization. Published February 10, 2023. Accessed March 23, 2023. https://www.who.int/news/item/10-02-2023-who-sends-health-supplies-to-reach-400-000-people-impacted-by-the-earthquakes-in-t-rkiye-and-the-syrian-arab-republic Google Scholar
Nocchi, R, Giorgi, P. Medici ospedalieri in prima linea contro il virus, “ma mancano camici e mascherine.” Agenzia Italia. Published March 16, 2020. Accessed September 10, 2023. https://www.agi.it/cronaca/news/2020-03-16/coronavirus-mascherine-medici-7583416/ Google Scholar
de Oliveira, T, Tegally, H. Will climate change amplify epidemics and give rise to pandemics? Science. 2023;381(6660):eadk4500. doi: 10.1126/science.adk4500 CrossRefGoogle ScholarPubMed
Er Kara, M, Ghadge, A, Bititci, US. Modelling the impact of climate change risk on supply chain performance. Int J Prod Res. 2021;59(24):7317-7335. doi: 10.1080/00207543.2020.1849844 CrossRefGoogle Scholar
Reuse of FFP2 Masks. Rijksinstituut voor Volksgezondheid en Milieu. Published March 17, 2020. Accessed March 22, 2023. https://www.rivm.nl/en/documenten/reuse-of-ffp2-masks Google Scholar
Stellungsnahme der Deutschen Gesellschaft für Sterilgutversorgung (DGSV) zur “Wiederaufbereitung” von Schutzmasken im Rahmen der “Coronapandemie” mit Bezug auf die Veröffentlichung der Dokumentes “Vorlage für den Krisenstab der Bundesregierung/Einsatz von Schutzmasken in Einrichtungen des Gesundheitswesens” vom 01.04.2020. Deutsche Gesellschaft für Sterilgutversorgung e.V. Published April 5, 2020. Accessed March 22, 2023. https://www.dgsv-ev.de/wp-content/uploads/2020/04/Stellungnahme-DGSV-Dekontamination-FFP-Masken-2.pdf Google Scholar
Blacky, A, Buchrieser, V, Freundlinger, T, et al. Stellungnahme des Fachausschusses Prüfwesen der ÖGSV zur Aufbereitung von Einmal-Schutzmasken in der Corona-Krise. ÖGSV. Published March 20, 2020. Accessed March 22, 2023. https://oegsv.com/wp/wp-content/uploads/Stellungnahme-Aufbereitung-von-Einmalmasken_2.pdf Google Scholar
Peters, A, Lotfinejad, N, Palomo, R, et al. Decontaminating N95/FFP2 masks for reuse during the COVID-19 epidemic: a systematic review. Antimicrob Resist Infect Control. 2021;10:144. doi: 10.1186/s13756-021-00993-w CrossRefGoogle ScholarPubMed
Vasilyak, LM. Physical methods of disinfection (a review). Plasma Phys Rep. 2021;47(3):318-327. doi: 10.1134/S1063780X21030107 CrossRefGoogle Scholar
Kraft, S, Obst, U, Schwartz, T. Immunological detection of UV induced cyclobutane pyrimidine dimers and (6–4) photoproducts in DNA from reference bacteria and natural aquatic populations. J Microbiol Methods. 2011;84(3):435-441. doi: 10.1016/j.mimet.2011.01.004 Google ScholarPubMed
Was Ist UV-Strahlung? Bundesamt für Strahlenschutz. Published March 29, 2022. Accessed March 1, 2023. https://www.bfs.de/DE/themen/opt/uv/einfuehrung/einfuehrung_node.html Google Scholar
Bestrahlungskammer BS-02 Anleitung. Opsytec Dr. Gröbel GmbH. Published December 15, 2021. Accessed September 14, 2023. https://www.opsytec.de/fileadmin/user_upload/products/downloads/Anleitungen/Bedienungsanleitung_BS-02.pdf Google Scholar
Opsytec Product Information Bestrahlungskammer BS-02. Opsytec Dr. Gröbel GmbH. Accessed September 14, 2023. https://www.opsytec.de/fileadmin/user_upload/products/downloads/d_bs02.pdf Google Scholar
Deutsches Institut für Normung e.V. DIN 10113-2:2023-02 Horizontales Verfahren Zur Bestimmung Des Oberflächenkeimgehaltes Und Nachweis von Bestimmten Mikroorganismen Auf Einrichtungs- Und Bedarfsgegenständen Entlang Der Lebensmittelkette – Teil 2: Verfahren Mit Nährmedienbeschichteten Entnahmevorrichtungen (Abklatschverfahren). Beuth Verlag GmbH; 2023.Google Scholar
Park, AM, Khadka, S, Sato, F, et al. Bacterial and fungal isolation from face masks under the COVID-19 pandemic. Sci Rep. 2022;12(1):11361. doi: 10.1038/s41598-022-15409-x CrossRefGoogle ScholarPubMed
Nicolau, T, Filho, NG, Zille, A. Ultraviolet-C as a viable reprocessing method for disposable masks and filtering facepiece respirators. Polymers. 2021;13(5):801. doi: 10.3390/polym1305080 CrossRefGoogle ScholarPubMed
Lindsley, WG, Martin, SB, Thewlis, RE, et al. Effects of ultraviolet germicidal irradiation (UVGI) on N95 respirator filtration performance and structural integrity. J Occup Environ Hyg. 2015;12(8):509-517. doi: 10.1080/15459624.2015.1018518 CrossRefGoogle ScholarPubMed
Masjoudi, M, Mohseni, M, Bolton, JR. Sensitivity of bacteria, protozoa, viruses, and other microorganisms to ultraviolet radiation. J Res Natl Inst Stand Technol. 2021;126:126021. doi: 10.6028/jres.126.021 CrossRefGoogle Scholar
Kandi, V, Palange, P, Vaish, R, et al. Emerging bacterial infection: identification and clinical significance of Kocuria species. Cureus. 2016;8(8):e731. doi: 10.7759/cureus.731 Google ScholarPubMed
Davis, CP. Normal flora. In: Baron, S, ed. Medical Microbiology. 4th ed. University of Texas Medical Branch at Galveston; 1996.Google Scholar
McKinney, CW, Pruden, A. Ultraviolet disinfection of antibiotic resistant bacteria and their antibiotic resistance genes in water and wastewater. Environ Sci Technol. 2012;46(24):13393-13400. doi: 10.1021/es303652q CrossRefGoogle ScholarPubMed
Fisher, EM, Shaffer, RE. A method to determine the available UV-C dose for the decontamination of filtering facepiece respirators. J Appl Microbiol. 2011;110(1):287-295. doi: 10.1111/j.1365-2672.2010.04881.x CrossRefGoogle ScholarPubMed
Baluja, A, Arines, J, Vilanova, R, et al. UV light dosage distribution over irregular respirator surfaces. Methods and implications for safety. J Occup Environ Hyg. 2020;17(9):390-397. doi: 10.1080/15459624.2020.1786576 CrossRefGoogle ScholarPubMed
Papale, G, De Palma, I, Amodeo, D, et al. Facemasks and public health: analysis of bacterial contamination in FFP2 masks. Eur J Public Health. 2022;32(3):ckac131.347. doi: 10.1093/eurpub/ckac131.347 CrossRefGoogle Scholar
UVC-Lichtdurchlässige Anwendungen. Buitink Technology. Accessed March 16, 2023. https://www.buitink-technology.com/de/miscellaneous/uvc-lichtdurchlaessige-anwendungen/ Google Scholar
Weaver, DT, McElvany, BD, Gopalakrishnan, V, et al. UV decontamination of personal protective equipment with idle laboratory biosafety cabinets during the COVID-19 pandemic. PLoS One. 2021;16(7):e0241734. doi: 10.1371/journal.pone.0241734 CrossRefGoogle ScholarPubMed
Kayani, BJ, Weaver, DT, Gopalakrishnan, V, et al. UV-C tower for point-of-care decontamination of filtering facepiece respirators. Am J Infect Control. 2021;49(4):424-429. doi: 10.1016/j.ajic.2020.11.010 CrossRefGoogle ScholarPubMed
Li, DF, Alhmidi, H, Scott, JG, et al. A simulation study to evaluate contamination during reuse of N95 respirators and effectiveness of interventions to reduce contamination. Infect Control Hosp Epidemiol. 2022;43(6):764-769. doi: 10.1017/ice.2021.218 CrossRefGoogle ScholarPubMed
REGULATION (EU) 2016/425 OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 9 March 2016 on personal protective equipment and repealing Council Directive 89/686/EEC. The European Parliament and the Council of the European Union. Official Journal of the European Union. Published March 31, 2016. Accessed September 13, 2023. https://eur-lex.europa.eu/legal-content/EN/TXT/HTML/?uri=CELEX%3A32016R0425 Google Scholar
Morocco Earthquake: MSF Teams Witness “Horrible Devastation.” Doctors Without Borders – USA. Published September 11, 2023. Accessed September 13, 2023. https://www.doctorswithoutborders.org/latest/morocco-earthquake-msf-teams-witness-horrible-devastation Google Scholar
Zhang, L, Liu, X, Li, Y, et al. Emergency medical rescue efforts after a major earthquake: lessons from the 2008 Wenchuan earthquake. Lancet. 2012;379(9818):853-861. doi: 10.1016/S0140-6736(11)61876-X CrossRefGoogle Scholar
Kouadio, IK, Aljunid, S, Kamigaki, T, et al. Infectious diseases following natural disasters: prevention and control measures. Expert Rev Anti Infect Ther. 2012;10(1):95-104. doi: 10.1586/eri.11.155 CrossRefGoogle ScholarPubMed
Figure 0

Figure 1. Schematic top-down view of the irradiation chamber with decreases of irradiation efficiency in the different areas.16 The door of the chamber is on the bottom of the figure. The masks are figured in white; the metallic mask holders are figured in transparent white.

Figure 1

Table 1. Manufacturer, model, EN149 mask type: bluebec, model BB203, FFP2NR; MUSK, MUSK21, FFP2NR; Sentias, DE.W42-A, FFP2NR; Amoedos Healthcare; DMaske, 2a, FFP2NR; Mea Vita, HKN001, FFP2NR; Guangdong YIDAO medical technology, YPHD, KN95

Figure 2

Figure 2. Total CFU/25cm² for the different irradiation schemes for different irradiaton durations in seconds. Red: Inside irradiation, time-dependent reduction between 3 and 30 seconds, then stable values between 30 and 120 with a maximum of 2 CFU/25cm². Blue: Outside irradiation between 30 and 120 seconds, no time-dependent reduction. Green: both sides of irradiation (inside before outside). Time-dependent reduction between 30 and 60 seconds, then stable values with a maximum of 2 CFU/25cm².