Hostname: page-component-586b7cd67f-tf8b9 Total loading time: 0 Render date: 2024-11-24T16:49:27.886Z Has data issue: false hasContentIssue false

Shunt reduction to pulmonary arteriovenous malformations using a modified covered stent

Published online by Cambridge University Press:  09 July 2012

I. Ricardo Argueta-Morales
Affiliation:
Department of Pediatric Cardiothoracic Surgery, The Heart Center, Arnold Palmer Hospital for Children, Orlando, Florida, United States of America
Robyn M. Hathaway
Affiliation:
Pediatric Cardiac Catheterization, The Heart Center, Arnold Palmer Hospital for Children, Orlando, Florida, United States of America
David G. Nykanen*
Affiliation:
Pediatric Cardiac Catheterization, The Heart Center, Arnold Palmer Hospital for Children, Orlando, Florida, United States of America
*
Correspondence to: Dr D. G. Nykanen, MD, Pediatric Cardiac Catheterization, The Heart Center, Arnold Palmer Hospital for Children, 50 West Sturtevant Street, Orlando, Florida 32806, United States of America. Tel: +1 321 843 3294; Fax: +1 321 841 4260; E-mail: [email protected]

Abstract

Pulmonary arteriovenous malformations in patients with congenital heart disease have been associated with interruption of hepatic venous return to the lungs. We report a novel technique to improve systemic saturation using a modified covered stent in a patient with unilateral left pulmonary arteriovenous malformations in the setting of a Fontan circulation.

Type
Brief Report
Copyright
Copyright © Cambridge University Press 2012 

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

1. Nazarian, GK, Qian, Z, Vlodaver, Z, et al. Evaluation of a new vascular occlusion device. Invest Radiol 1993; 28: 11651169.Google Scholar
2. Pedra, CA, Pihkala, J, Benson, LN, Freedom, RM, Nykanen, D. Stent implantation to create interatrial communications in patients with complex congenital heart disease. Catheter Cardiovasc Interv 1999; 47: 310313.Google Scholar
3. Kretschmar, O, Sglimbea, A, Corti, R, Knirsch, W. Shunt reduction with a fenestrated Amplatzer device. Catheter Cardiovasc Interv 2010; 76: 564571.CrossRefGoogle ScholarPubMed
4. Van Den Bogaert-Van Heesvelde, AM, Derom, F, Kunnen, M, Van Egmond, H, Devlon-Blancquert, A. Surgery for arteriovenous fistulas and dilated vessels in the right lung after the Glenn procedure. J Thorac Cardiovasc Surg 1978; 76: 195197.CrossRefGoogle ScholarPubMed
5. Farra, H, Balzer, DT. Transcatheter occlusion of a large pulmonary arteriovenous malformation using the Amplatzer vascular plug. Pediatr Cardiol 2005; 26: 683685.CrossRefGoogle ScholarPubMed
6. Freedom, RM, Yoo, SJ, Perrin, D. The biological “scrabble” of pulmonary arteriovenous malformations: considerations in the setting of cavopulmonary surgery. Cardiol Young 2004; 14: 417437.Google Scholar
7. AboulHosn, J, Danon, S, Levi, D, Castellon, Y, Child, J, Moore, J. Regression of pulmonary arteriovenous malformations after transcatheter reconnection of the pulmonary arteries in patients with unidirectional Fontan. Congenit Heart Dis 2007; 2: 179184.CrossRefGoogle ScholarPubMed
8. McElhinney, DB, Kreutzer, J, Lang, P, Mayer, JE Jr, del Nido, PJ, Lock, JE. Incorporation of the hepatic veins into the cavopulmonary circulation in patients with heterotaxy and pulmonary arteriovenous malformations after a Kawashima procedure. Ann Thorac Surg 2005; 80: 15971603.CrossRefGoogle ScholarPubMed
9. Sernich, S, Ross-Ascuitto, N, Dorotan, J, DeLeon, S, Ascuitto, RJ. Surgical improvement of hepatic venous mixing to resolve systemic arterial hypoxemia associated with post-Fontan pulmonary arteriovenous fistulae. Tex Heart Inst J 2009; 36: 480482.Google Scholar
10. Kim, SJ, Bae, EJ, Lee, JY, Lim, HG, Lee, C, Lee, CH. Inclusion of hepatic venous drainage in patients with pulmonary arteriovenous fistulas. Ann Thorac Surg 2009; 87: 548553.CrossRefGoogle ScholarPubMed