Hostname: page-component-cd9895bd7-q99xh Total loading time: 0 Render date: 2024-12-18T20:23:54.412Z Has data issue: false hasContentIssue false

Electronic phenotyping of community-acquired pneumonia: A tool for inpatient syndrome-specific antimicrobial stewardship

Published online by Cambridge University Press:  29 September 2023

Abstract

Core share and HTML view are not available for this content. However, as you have access to this content, a full PDF is available via the ‘Save PDF’ action button.

Background: Using patient data from the electronic health record (EHR) and computer logic, an “electronic phenotype” can be created to identify patients with community-acquired pneumonia (CAP) in real time to assist with syndrome-specific antimicrobial stewardship efforts.1 We adapted and validated the performance of an inpatient CAP electronic phenotype for antimicrobial stewardship interventions. Methods: An automated scoring system was created within the EHR (Epic Systems) to identify hospitalized patients with CAP based on the variables and logic listed in Fig. 1B. We adapted a score used by the Michigan Hospital Medicine Safety Consortium (HMS) to identify patients with CAP, with additions made to improve sensitivity (Fig. 1).1 The score can be displayed in a column within the EHR patient list (Fig. 2). We validated the electronic phenotype via chart review of all hospitalized patients on systemic antimicrobials admitted to a medicine team consecutively between November 8 and 18, 2021. Patients who were readmitted within the validation time frame were excluded. We assessed the performance of the electronic phenotype by comparing the score to manual chart review, where “CAP diagnosis” was defined as (1) mention of “pneumonia” or “CAP” as part of the differential diagnosis in the admission documentation, (2) antimicrobials were started within 48 hours of admission, and (3) radiographic findings were suggestive of pneumonia. After initial evaluation, the scoring system was adjusted, and performance was re-evaluated during prospective audit and feedback performed on EHR CAP–positive patients over 13 days between July 2022 and December 2022. Results: We included 191 patients in our initial validation cohort. The CAP score had high sensitivity (95.83%), specificity (92.2%), and negative predictive value (99.35%), though lower positive predictive value (63.89%) was noted (Table 2). The rules were further refined to include bloodstream infection only with Haemophilus influenza or Streptococcus pneumoniae in rule 2B, and azithromycin was removed from “CAP antibiotics.” After these changes, repeated evaluation of 88 patients with positive CAP EHR score was performed, and only 20 (23%) were considered false-positive results. Conclusions: Electronic phenotypes can be used to create automated tools to identify patients with CAP with reasonable performance. Data from this tool can be used to guide more focused antimicrobial stewardship interventions and clinical decision support in the future. Reference: Vaughn VM, et al. A statewide collaborative quality initiative to improve antibiotic duration and outcomes in patients hospitalized with uncomplicated community-acquired pneumonia. Clin Infect Dis 2022;75:460–467.

Disclosures: None

Type
Implementation Science
Creative Commons
Creative Common License - CCCreative Common License - BY
This is an Open Access article, distributed under the terms of the Creative Commons Attribution licence (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted re-use, distribution, and reproduction in any medium, provided the original work is properly cited.
Copyright
© The Author(s), 2023. Published by Cambridge University Press on behalf of The Society for Healthcare Epidemiology of America