Hostname: page-component-cd9895bd7-lnqnp Total loading time: 0 Render date: 2024-12-22T07:07:38.677Z Has data issue: false hasContentIssue false

Effect of relative humidity on hydrogen peroxide production in water droplets

Published online by Cambridge University Press:  27 July 2021

Maria T. Dulay
Affiliation:
Department of Chemistry, Stanford University, Stanford, CA94305, USA
Carlos Alberto Huerta-Aguilar
Affiliation:
Department of Chemistry, Stanford University, Stanford, CA94305, USA
Christian F. Chamberlayne
Affiliation:
Department of Chemistry, Stanford University, Stanford, CA94305, USA
Richard N. Zare*
Affiliation:
Department of Chemistry, Stanford University, Stanford, CA94305, USA
Adriaan Davidse
Affiliation:
PO Box 93167 Headon PO Burlington, ONL7M 4A3, Canada
Sinisa Vukovic
Affiliation:
MineRP, 333 Bay Street, Toronto, ONM5H 2T6, Canada
*
*Author for correspondence: Richard N. Zare, E-mail: [email protected]
Rights & Permissions [Opens in a new window]

Abstract

A plot of H2O2 concentration as a function of %RH in the laboratory during the generation of mist using Biograde water. Each point represents a single measurement.

Mist is generated by ultrasonic cavitation of water (Fisher Biograde, pH 5.5–6.5) at room temperature (20–25 °C) in open air with nearly constant temperature (22–25 °C) but varying relative humidity (RH; 24–52%) over the course of many months. Water droplets in the mist are initially about 7 μm in diameter at about 50% RH. They are collected, and the concentration of hydrogen peroxide (H2O2) is measured using commercial peroxide test strips and by bromothymol blue oxidation. The quantification method is based on the Fenton chemistry of dye degradation to determine the oxidation capacity of water samples that have been treated by ultrasonication. It is found that the hydrogen peroxide concentration varies nearly linearly with RH over the range studied, reaching a low of 2 parts per million (ppm) at 24% RH and a high of 6 ppm at 52% RH. Some possible public health implications concerning the transmission of respiratory viral infections are suggested for this threefold change in H2O2 concentration with RH.

Type
Research Article
Creative Commons
Creative Common License - CCCreative Common License - BYCreative Common License - NCCreative Common License - SA
This is an Open Access article, distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike licence (http://creativecommons.org/licenses/by-nc-sa/4.0/), which permits non-commercial re-use, distribution, and reproduction in any medium, provided the same Creative Commons licence is included and the original work is properly cited. The written permission of Cambridge University Press must be obtained for commercial re-use.
Copyright
© The Author(s), 2021. Published by Cambridge University Press

Introduction

Interest in understanding the role of relative humidity (RH) in modulating the transmission and seasonality of infectious diseases has resulted in an increase in recent published studies (Han et al., Reference Han, Ran, Chan, Mak, Suen, Cowling and Yang2020; Lin and Marr, Reference Lin and Marr2020; Moriyama et al., Reference Moriyama, Hugentobler and Iwasaki2020; Ma et al., Reference Ma, Pei, Shaman, Dubrow and Chen2021). It has been known for decades that respiratory droplets in ambient air evaporate until they reach equilibrium. Because respiratory droplets are saturated (Walker and Wells, Reference JEC and Wells1961) while ambient air typically is not, a vapour pressure gradient is produced between the droplet surface and the ambient air that is the driving force for evaporation, which has been shown to be influenced by RH (Marr et al., Reference Marr, Tang, Van Mullekom and Lakdawala2019). The equilibrium size of a droplet, which is attained within a few seconds (Nicas and Jones, Reference Nicas and Jones2009; Shaman and Kohn, Reference Shaman and Kohn2009; Halloran et al., Reference Halloran, Wexler and Ristenpart2012) is dependent on RH (Marr et al., Reference Marr, Tang, Van Mullekom and Lakdawala2019), and the size of the droplet determines its gravitational settling speed (Xie et al., Reference Xie, Ho, Li, Chwang and Seto2007; Božič and Kanduč, Reference Božič and Kanduč2021). The changes in chemistry within these smaller droplet sizes have been proposed as a cause of influenza virus degradation. The stability of viruses may depend on chemical events such as osmotic bursting or changes in pH that may alter a protein’s geometry (Marr et al., Reference Marr, Tang, Van Mullekom and Lakdawala2019). Virus inactivation at the air–water interface of an aerosolized droplet has also been proposed although the mechanism is poorly understood (Božič and Kanduč, Reference Božič and Kanduč2021).

Our own studies of water microdroplets offer insight into the chemistry that plays a role in the inactivation of pathogenic species. The chemical microenvironment of a water microdroplet involves the formation of reactive oxygen species (ROS), which includes the hydroxyl radical (•OH) and hydrogen peroxide (H2O2) because of the high electric field present at the air–water interface of a microdroplet (Lee et al., Reference Lee, Walker, Han, Kang, Prinz, Waymouth, Nam and Zare2019). Aqueous microdroplets of nominal 10-μm size have been shown to act as a bactericide in the inactivation of Escherichia coli and Salmonella typhimurium where the presence of ROS in microdroplets and the surface charge of microdroplets play roles in the destruction of these bacterial cells (Dulay et al., Reference Dulay, Lee, Mody, Narasimhan, Monack and Zare2020). In this study, the results show that the concentration of H2O2 in a water microdroplet has a linear relationship within a given range of RH that aligns with the seasonality of infectious diseases. It is suggested that understanding the role of RH in the formation of ROS will aid in designing methods to reduce or prevent the transmission of airborne infectious diseases.

Materials and methods

Chemicals and materials

Biograde water (Corning) was purchased from Fisher Scientific (Waltham, MA) and used without further purification. MQuant peroxide test strips for the colorimetric detection of H2O2 in the range of 0.5–25 ppm were purchased from Sigma-Aldrich (Milwaukee, WI) and stored at 4 °C. Bromothymol blue (BTB) and iron (II) sulphate (ferrous sulphate, FeSO4) were purchased from Sigma-Aldrich (Milwaukee, WI) and used as received.

A FITNATE ultrasonic mist maker was purchased from Amazon (Seattle, WA). This mist maker contained a 16 mm × 1.2 mm ceramic piezoelectric disc with a resonant frequency of 1.70 MHz and a resonant impedance of less than 1 Ω. The maximum spray volume was approximately 110 ml h−1. Becton–Dickinson 96-well microplates, Becton–Dickinson plastic petri dishes, and 1.5-ml Eppendorf tubes were purchased from Fisher Scientific (Waltham, MA). RH and temperature were recorded using a HOBO UX100–011 data logger (Onset Computer Corporation, Bourne, MA).

Instruments

An Azure Biosystems (Dublin, CA) absorbance microplate reader (450 nm) was used to monitor the Fenton reaction/BTB chemical assay. A HELOS 2750 Particle Size Analyzer (Sympatec GmbH, Clausthal-Zellerfeld, Germany) was used to measure the size of the water droplets produced from the mist maker.

Mist generation and collection

The mist maker was positioned at 45° from the bottom of a 500-ml beaker filled with a total volume of 250–300 ml of Biograde water. The angle was chosen so that the waterspout from the mist maker hits the beaker wall at a height approximately 1.6 cm from the surface of the water to minimise water loss from the beaker during the mist generation and collection. The total volume of Biograde water in the beaker containing the mist maker was brought to 250 ml. Operation of the mist maker was done under ambient environmental conditions. Mist was collected within the first 5–10 min of operation as it condensed into a plastic petri dish that was placed next to the beaker. No additional water was added to the beaker during the mist collection as the volume of water loss was minimal. The condensed mist was placed into Eppendorf tubes and immediately analysed using a chemical assay. The temperature of the water in the beaker did not exceed 27°C as measured with a thermometer. The laboratory RH was measured using the RH sensor described above which was located near the experimental setup. Measurements were recorded over many months so that the variation with RH of the room could be determined. The local RH surrounding the droplets in the mist is expected to be higher from the droplets’ evaporation and has not been measured. Nevertheless, it is expected to scale with the RH in the room.

H2O2 quantification

Test strip method

This semi-quantitative method involved the use of commercial MQuant H2O2 test strips. A test strip was placed for approximately 10 s into at least 50 μl of mist sample. Any colour change to blue was indicative of the presence of H2O2 and the shade of blue was compared to a colour chart on the test strip bottle. This test strip approach provided a rapid, but semi-quantitative measure of H2O2 concentration and was used primarily to confirm the presence of H2O2.

BTB chemical assay

This quantitative chemical assay is based on the Fenton reaction, with BTB as the OH radical scavenger. Stock solutions of 1.0 mM BTB and 5.0 mM ferrous sulphate (FeSO4), were prepared in Biograde water. For each sample analysis, 5 μl of BTB stock solution and 10 μl FeSO4 stock solution were added to 200 μl of mist sample to be analysed. An additional 35 μl of Biograde water was added to the mixture to bring the total volume to 250 μl. A control solution was prepared by mixing 5 μl BTB stock solution and 245 μl Biograde water for a final total volume of 250 μl. The blank was 250 μl of Biograde water. The changes in absorbance were converted to concentration, using Beer’s law where the molar absorptivity (ε) of BTB is 13,000 M−1 cm−1 at 450 nm. The second-order reaction rate was obtained by plotting 1/[BTB] as a function of time (s). The resulting slope was converted to apparent hydrogen peroxide concentration, [H2O2]app, from a calibration curve prepared using H2O2 concentrations ranging from 0 to 50 mg l−1. A calibration curve was prepared at the beginning of the experiments done on each day.

A volume of 250 μl of each calibration or test sample was added to a well in a 96-well plate. Absorbance measurements of each sample in each well were taken every 45 s at 450 nm for a total scan time of 25 min. To verify that oxidised BTB from a change in solution pH was not present during the reaction, the absorbance at 650 nm was monitored.

Mist droplet size measurement

To achieve a steady stream of mist flow to the focal point of the laser of the HELOS 2750 Particle Size Analyzer, the droplets in the mist were pulled into a tube attached to house vacuum. The tube was prepared by connecting 50-ml plastic Falcon tubes (30-mm i.d.) with two 25 mm × 75 mm glass slides positioned at the top and bottom of tubes arranged in series as shown in Scheme 1. The focal point of the laser was approximately 255 mm from the opening of the tube through which the mist entered. Two or four minutes after turning on the mist maker, size measurements were recorded for 1 s. The reference was taken at ambient conditions with the room light off in the absence of mist (mist maker off). The measurements were done in triplicate.

Scheme 1. Setup for droplet size measurements. The photo shows the laser light scattering off the droplets in the mist as they travelled through the tube while being suctioned under vacuum.

Results and discussion

The history of this experimental study might help to put our results and their limitations in better perspective. Once we understood that tiny water droplets could be used as a biocide (Dulay et al., Reference Dulay, Lee, Mody, Narasimhan, Monack and Zare2020) we turned our attention to exploring what factors might lead to the production of higher concentrations of H2O2. We examined various grades of water, the water temperature, and the possible addition of different solutes, such as salt and carbon dioxide, that might affect the H2O2 concentration. This study went on for many months, during which time we noticed that the results obtained were variable. This variability was traced to the percentage RH in the surrounding air caused by seasonal changes in the laboratory air environment. The present results are incomplete and should be regarded as only a start of the question of how %RH affects the H2O2 concentration in water droplets found in a mist. Certainly, a better study in the future would be to control the %RH and to vary it under our control. In this way we might cover a wider range of %RH, which would be desirable. Nevertheless, the results were to us so striking that we want to share them in their present form.

The size of water droplets in the ultrasonically generated mist was characterised by light scattering, as described above. The size distribution data were fitted to a normal log function whose peak is defined as the droplet diameter. Fig. 1 shows that the droplet diameter in the mist is 6.71 μm (n = 3, RSD = 0) with an average distribution density of 1.83 (n = 3, RSD = 0.70%). Droplet diameters ranged in size from 1 to 19.4 μm with a droplet distribution density of 0.081 and 0.044, respectively. Based on previous studies on the production of hydrogen peroxide in droplets formed by spraying water (Lee et al., Reference Lee, Walker, Han, Kang, Prinz, Waymouth, Nam and Zare2019) and condensing water vapour (Lee et al., Reference Lee, Han, Chaikasetsin, Marron, Waymouth, Prinz and Zare2020), these droplet sizes are expected to produce readily detectable concentrations of H2O2.

Fig. 1. Plot of droplet distribution density as a function of droplet diameter in mist generated by a mist maker immersed in approximately 300 ml Biograde water. Each plot represents 1 s of data acquisition: trial 1 (blue circles) with mist maker on for 2 min prior to measurement; trial 2 (orange circles) with mist maker on for 4 min prior to measurement; and trial 3 (grey circles) with mist maker on for 2 min prior to measurement. Trials 1 and 3 were acquired under identical conditions to test reproducibility.

The concentration of H2O2 present in the mist generated was determined using Fenton chemistry with BTB as the dye indicator. Fenton chemistry is rather complex and has been summarised elsewhere (Babuponnusami and Muthukumar, Reference Babuponnusami and Muthukumar2014). A pseudo-second-order dependence on the disappearance of the BTB concentration is observed at long time (Fig. 2a ). Its pseudo-second-order rate constant is observed to have a linear dependence on the initial H2O2 concentration (Fig. 2b ). While Fig. 2 only shows 0.1–8 ppm, this linear dependence was verified for the range of 0.1–150 ppm (R 2 = 0.997). A calibration curve for determining the H2O2 initial concentration was constructed from the pseudo-second-order rate constant in BTB. Hydrogen peroxide test strips were used to confirm the presence of H2O2 in the mist samples.

Fig. 2. (a) Plot of time versus 1/[BTB] for 0–8 ppm H2O2. (b) Calibration curve created by plotting the rate constant k. as a function of [H2O2].

From the assay, the concentration of H2O2 present in mist was measured at different values of the RH percentage (%RH) in the laboratory. Fig. 3 shows the relationship between [H2O2] and %RH. As the %RH increases between the range of 24 and 52%, at 25°C, the concentration of H2O2 increases linearly. These results might be compared to what has been reported for the H2O2 concentration in droplets formed from condensed water vapour on a cold substrate (Lee et al., Reference Lee, Han, Chaikasetsin, Marron, Waymouth, Prinz and Zare2020). It was found that at 0.5 min, the average microdroplet diameter was 4.0 ± 2.7 μm, and the H2O2 production yield was less than 1.0 ppm. Under continuous cooling, the microdroplet diameter increased to an average value of 7.7 ± 5.7 μm after 2 min. The H2O2 production yield reached a maximum value of ∼3.9 ppm at 2 min. After 5 min, microdroplets continued to grow with an average diameter of 12.5 μm. At this time point, droplets with diameters of ∼100 μm or larger were formed and the concentration of H2O2 dropped below the level of detection, being so diluted by the added amount of condensed water. Unfortunately, the %RH was not recorded in this earlier study, so it is difficult to make the comparison quantitative. It is possible that the higher hydrogen peroxide concentration reported in this study arises in part from ultrasonic cavitation used in our mist maker, which is known to produce radicals (Riesz et al., Reference Riesz, Berdahl and Christman1985) although as will be explained in what follows, this cannot explain the variation of H2O2 concentration with %RH.

Fig. 3. A plot of H2O2 concentration as a function of %RH in the laboratory during the generation of mist using Biograde water. Each point represents a single measurement.

The mechanism for H2O2 generation in aqueous microdroplets surrounded by a hydrophobic medium is presently not completely understood. We know that H2O2 formation occurs rapidly in less than a millisecond as demonstrated by chemical trapping of H2O2 reaction products in a spray in air entering a mass spectrometer (Gao et al., Reference Gao, Jin, Lee and Zare2019). Microdroplets are known to have a strong electric field at the interface and an internal electric double layer (EDL) (Chamberlayne and Zare, Reference Chamberlayne and Zare2020; Xiong et al., Reference Xiong, Lee, Zare and Min2020). A leading theory for H2O2 production is that it arises from the recombination of hydroxyl radicals at the air–water interface, which is promoted by this special environment (Lee et al., Reference Lee, Walker, Han, Kang, Prinz, Waymouth, Nam and Zare2019). The hydroxyl radicals are thought to originate from hydroxide anions that lose an electron promoted by the strong electric field from the EDL (Lee et al., Reference Lee, Walker, Han, Kang, Prinz, Waymouth, Nam and Zare2019). There appears to be a steady-state amount of H2O2 formed which depends on the radius of the droplet. Again, the mechanism behind this has not been established. The nearly linear variation of the H2O2 concentration with %RH, evident in Fig. 3, might offer a clue to advancing our understanding of this phenomenon.

All droplets formed from the mist maker are believed to start with the same H2O2 concentration but then undergo evaporation at different rates depending on the RH. The rate of evaporation depends on many factors and has been reviewed elsewhere (Božič and Kanduč, Reference Božič and Kanduč2021). H2O2 becomes increasingly concentrated in the remaining water droplet (Hultman et al., Reference Hultman, Hill and McDonnell2007). If evaporation were the only mechanism, then it would be expected that the H2O2 would accumulate in the evaporating droplets, such that the H2O2 concentration would increase as the RH is lowered for which evaporation proceeds more rapidly. But this would lead to exactly the opposite trend to what is observed in Fig. 3. This indicates that whatever mechanism is responsible for the H2O2 formation also has a loss mechanism that establishes a radius-dependent steady-state condition for the H2O2 amount. This loss mechanism might be a combination of decomposition of H2O2 and evaporation of the entire droplet. Further support for this loss mechanism comes from our observation that when the temperature of the Biograde water was raised, the production of H2O2 in the collected droplets decreased.

In understanding our observations, it is important to realise that these experiments are not done with an isolated droplet but rather in a mist of droplets. If one creates mist, many of the nanosized droplets constituting mist will aggregate into micron-sized water droplets (and then condense for our measurements). On the other hand, if one injects microdroplets into vacuum many droplets will evaporate to nanodroplets. Evaporation rates and evaporation rate constants (related to surface tension) depend on the droplet sizes. But so do the aggregation rates which also depend on the amounts of droplets. Mist and droplets exist in a dynamic equilibrium, where some mist is turning into droplets and some droplets disintegrating into mist. The %RH in the mist is expected to be much higher than the %RH in the surrounding air. However, the formation and steady-state behaviour of the mist depend on the rate of evaporation, and therefore the %RH of the surrounding air affects the resulting H2O2 concentration.

We know that at the extremes of small water clusters and very large water droplets, there is no detectable presence of H2O2. This reasoning suggests that we are observing a ‘Goldilocks effect’ in which droplets that are too large or too small have diminished H2O2 concentration compared to intermediate sizes. Let us consider how the optimal balance between these two extremes might occur. The falloff in H2O2 concentration as the size of the water droplet increases is relatively easy to explain. The reduction in surface area compared to volume washes out any surface area dependent effects. The falloff in H2O2 concentration as the size of the water droplet decreases is less intuitive. We suggest it is coming from interplay with the EDL inside the microdroplet. As the droplet size shrinks beyond some limit, the hydrogen peroxide generating mechanism is turned off and the loss mechanism becomes dominant. There exists a transition from nanoscale droplets, wherein the EDL of the nanodroplet from opposite sides of the droplet fully overlap, to larger droplets wherein the EDL is at the surface with a separate interior bulk solution to the microdroplet. This may help explain the Goldilocks effect observed. While we do not fully understand the mechanism, it possibly involves the interfacial solvation energy of the surface. The use of such energy in a mechanism could easily necessitate the existence of a bulk region in contact with a surface region and thus be prevented from existing in nanoscale droplets.

Fig. 3 also shows a remarkable increase by about a factor of three in the H2O2 concentration as %RH increases from 24 to 52%. Previous work (Dulay et al., Reference Dulay, Lee, Mody, Narasimhan, Monack and Zare2020) have clearly demonstrated that the ROS in sprayed water droplets (which we call aquaROS) are able to punch holes in the membranes of some bacteria causing them to be no longer viable. Preliminary results we have obtained on tobacco mosaic virus also show the killing power of aquaROS. Thus, we hypothesise that the water droplets at the high end of the percentage RH that we studied would also be a more potent bactericide and virucide. This conjecture is consistent with the observations presented elsewhere that viruses are effectively killed in small water droplets when the RH is in the range of 40–60% but survive much better when the RH is less than 40% or greater than 60% (Birks and Rowlen, Reference Birks and Rowlen2020; Lin and Marr, Reference Lin and Marr2020; Božič and Kanduč, Reference Božič and Kanduč2021). Although not without some controversy (Greenhalgh et al., Reference Greenhalgh, Jimenez, Prather, Tufekci, Fisman and Schooley2021; Heneghan et al., Reference Heneghan, Spencer, Brassey, Plüddemann, Onakpoya, Evans, Conly and Jefferson2021; Niazi et al., Reference Niazi, Growth, Spann and Johnson2021), it does seem well established that viral respiratory diseases are primarily transmitted by airborne droplets. A number of public health consequences have been suggested (Davidse and Vukovic, Reference Davidse and Vukovic2020; Courtney and Bax, Reference Courtney and Bax2021). The results of the present study might provide a chemical basis for why maintaining %RH between 40 and 60% promotes human health.

Acknowledgements

C.A.H-A. would like to thank CONACyT for a postdoctoral fellowship. This work was supported by a SPARK Program in Translational Research at Stanford grant (Title: Spontaneously Formed Reactive Oxygen Species from Water for Pathogen Disinfection) and the US Air Force Office of Scientific Research through Basic Research Initiative grant (No. AFOSR FA9550-12-1-0400).

Author contributions

R.N.Z., M.T.D., C.A.H-A. and C.F.C. conceived the study. R.N.Z., M.T.D., C.A.HA., C.F.C., A.D., and S.V. interpreted the experimental results. M.T.D. and C.A.H-A. performed the H2O2 quantitation experiments. M.T.D. and C.F.C. performed the droplet size measurements. All authors wrote the manuscript.

Conflicts of interest

The authors declare no conflicts of interest.

Open Peer Review

To view the open peer review materials for this article, please visit http://dx.doi.org/10.1017/qrd.2021.6.

Footnotes

Present address: Maria T. Dulay, Department of Radiology, Stanford School of Medicine, Stanford, CA 94305, USA

Present address: Carlos Alberto Huerta-Aguilar, School of Engineering and Sciences, Tecnologico de Monterrey, 5718 Atlixcáyotl, 72453 Puebla, Mexico

Maria T. Dulay and Carlos Alberto Huerta-Aguilar contributed equally to this work.

The original version of this article was published with an incorrect ORCID ID for an author. A notice detailing this has been published and the error rectified in the online PDF and HTML copies.

References

Babuponnusami, A and Muthukumar, K (2014) A review on Fenton and improvements to the Fenton process for wastewater treatment. Journal of Environmental Chemical Engineering 2, 557572.CrossRefGoogle Scholar
Birks, JW and Rowlen, KL (2020) Maintaining Classroom Humidity at 40–60% RH Would Reduce Transmission of Respiratory Viruses, Preprint September 2020. Available at https://www.researchgate.net/lab/John-W-Birks-Lab.Google Scholar
Božič, A and Kanduč, M (2021) Relative humidity in droplet and airborne transmission of disease. Journal of Biological Physics 47, 129.CrossRefGoogle ScholarPubMed
Chamberlayne, CF and Zare, RN (2020) Simple model for the electric field and spatial distribution of ions in a microdroplet. The Journal of Chemical Physics 152, 184702.CrossRefGoogle Scholar
Courtney, JM and Bax, A (2021) Hydrating the respiratory tract: An alternative explanation why masks lower severity of COVID-19. Biophysical Journal 120, 9941000.CrossRefGoogle ScholarPubMed
Davidse, A and Vukovic, S (2020) Letter: Ex Vivo Amplification of Immune Response - Mechanism of Virucide within Exhaled Droplets of Infected Host. Preprint December 2020. http://dx.doi.org/10.13140/RG.2.2.32536.83204 CrossRefGoogle Scholar
Dulay, MT, Lee, JK, Mody, AC, Narasimhan, R, Monack, DM and Zare, RN (2020) Spraying small water droplets acts as a bacteriocide. QRB Discovery 1(e3), 18.CrossRefGoogle Scholar
Gao, D, Jin, F, Lee, JK and Zare, RN (2019) Aqueous microdroplets containing only ketones or aldehydes undergo Dakin and Baeyer–Villiger reactions. Chemical Science 10, 1097410978.CrossRefGoogle ScholarPubMed
Greenhalgh, T, Jimenez, JL, Prather, KA, Tufekci, Z, Fisman, D and Schooley, R (2021) Ten scientific reasons in support of airborne transmission of SARS-CoV-2. Lancet 397, 16031605.CrossRefGoogle ScholarPubMed
Halloran, SK, Wexler, AS and Ristenpart, WD (2012) A comprehensive breath plume model for disease transmission via expiratory aerosols. PLoS One 7, e7088.CrossRefGoogle ScholarPubMed
Han, L, Ran, J, Chan, K-H, Mak, Y-M, Suen, L, Cowling, BJ and Yang, L (2020) Indoor environmental factors and acute respiratory illness in a prospective cohort of community-dwelling older adults. The Journal of Infectious Diseases 222, 967978.CrossRefGoogle Scholar
Heneghan, C, Spencer, E, Brassey, J, Plüddemann, A, Onakpoya, IJ, Evans, DH, Conly, JM and Jefferson, T (2021) SARS-CoV-2 and the role of airborne transmission: A systematic review. F1000Research 10, 232. https://doi.org/10.12688/f1000research.52091.1 CrossRefGoogle Scholar
Hultman, C, Hill, A and McDonnell, G (2007) The physical chemistry of decontamination with gaseous hydrogen peroxide. Pharmaceutical Engineering 27, 2232.Google Scholar
Lee, JK, Han, HS, Chaikasetsin, S, Marron, DP, Waymouth, RM, Prinz, FB and Zare, RN (2020) Condensing water vapor to droplets generates hydrogen peroxide. PNAS 117, 3093430941.CrossRefGoogle ScholarPubMed
Lee, JK, Walker, KL, Han, HS, Kang, J, Prinz, FB, Waymouth, RM, Nam, HG and Zare, RN (2019) Spontaneous generation of hydrogen peroxide from aqueous microdroplets. PNAS 116, 1929419298.CrossRefGoogle ScholarPubMed
Lin, K and Marr, LC (2020) Humidity-dependent decay of viruses, but not bacteria, in aerosols and droplets follows disinfection kinetics. Environmental Science & Technology 54, 10241032.CrossRefGoogle Scholar
Ma, Y, Pei, S, Shaman, J, Dubrow, R and Chen, K (2021) Role of meteorological factors in the transmission of SARS-CoV-2 in the United States. Nature Communications 12, 3602.CrossRefGoogle ScholarPubMed
Marr, LC, Tang, JW, Van Mullekom, J and Lakdawala, SS (2019) Mechanistic insights into the effect of humidity on airborne influenza virus survival, transmission, and incidence. Journal of the Royal Society Interface 16, 20180298.CrossRefGoogle ScholarPubMed
Moriyama, M, Hugentobler, WJ and Iwasaki, A (2020) Seasonality of respiratory viral infections. Annual Review of Virology 7, 2.12.19.CrossRefGoogle ScholarPubMed
Niazi, S, Growth, R, Spann, K and Johnson, GR (2021) The role of respiratory droplet physicochemistry in limiting and promoting the airborne transmission of human coronaviruses: A critical review. Environmental Pollution 276, 115767.CrossRefGoogle ScholarPubMed
Nicas, M and Jones, RM (2009) Relative contributions of four exposure pathways to influenza infection risk. Risk Analysis 29, 12911303.CrossRefGoogle ScholarPubMed
Riesz, P, Berdahl, D and Christman, CL (1985) Free radical generation by ultrasound in aqueous and nonaqueous solutions. Environmental Health Perspectives 64, 233252.CrossRefGoogle ScholarPubMed
Shaman, J and Kohn, M (2009) Absolute humidity modulates influenza survival, transmission, and seasonality. PNAS 106, 32433248.CrossRefGoogle ScholarPubMed
JEC, Walker and Wells, RE (1961) Heat and water exchange in the respiratory tract. The American Journal of Medicine 30, 259267.Google Scholar
Xie, X, Ho, PL, Li, Y, Chwang, ATY and Seto, WH (2007) How far droplets can move in indoor environments – Revisiting the Wells evaporation–falling curve. Indoor Air 17, 211225.CrossRefGoogle ScholarPubMed
Xiong, H, Lee, JK, Zare, RN and Min, W (2020) Strong electric field observed at the interface of aqueous microdroplets. Journal of Physical Chemistry Letters 11, 74237428.CrossRefGoogle Scholar
Figure 0

Scheme 1. Setup for droplet size measurements. The photo shows the laser light scattering off the droplets in the mist as they travelled through the tube while being suctioned under vacuum.

Figure 1

Fig. 1. Plot of droplet distribution density as a function of droplet diameter in mist generated by a mist maker immersed in approximately 300 ml Biograde water. Each plot represents 1 s of data acquisition: trial 1 (blue circles) with mist maker on for 2 min prior to measurement; trial 2 (orange circles) with mist maker on for 4 min prior to measurement; and trial 3 (grey circles) with mist maker on for 2 min prior to measurement. Trials 1 and 3 were acquired under identical conditions to test reproducibility.

Figure 2

Fig. 2. (a) Plot of time versus 1/[BTB] for 0–8 ppm H2O2. (b) Calibration curve created by plotting the rate constant k. as a function of [H2O2].

Figure 3

Fig. 3. A plot of H2O2 concentration as a function of %RH in the laboratory during the generation of mist using Biograde water. Each point represents a single measurement.

Review: Effect of Relative Humidity on Hydrogen Peroxide Production in Water Droplets — R0/PR1

Conflict of interest statement

Reviewer declares none.

Comments

Comments to Author: The manuscript expands on the earlier QRB report by Dulay, Zare, and co-workers on the antimicrobial effect of spontaneously generated H2O2 in microdroplets.Here, the authors demonstrate that the H2O2 concentration in fluid from condensed droplets scales roughly linearly with room relative humidity (RH_room) and interpret this observation as a potential (perhaps plausible) explanation for the seasonality of respiratory diseases.Indeed, virus viability lifetime in aerosolized droplets is known to depend on RH_room and solution chemistry is likely to play a role in this viral inactivation.The alternate explanationthat RH_room-dependent osmotic bursting (Marr) applies is likely also true, but would lead to a very rapid inactivation during the first few seconds that a virus-droplet reaches its pseudo-equilibrium size after becoming airborne, but not to the slow decay in virus viability that has been documented for much longer time scales.Hence, H2O2-mediated inactivation which only will take place if the aerosolized droplet doesn't fully desiccate plausibly plays a plausible role in this process.

The authors correctly point out that the effective humidity in the droplet cloud differs from RH_room but argue that there is a relation between the two, which is undoubtedly true.The authors also argue that differential evaporation of the droplet would increase at lower RH_room (because the vapor pressure of H2O2 is far lower than that of H2O), opposite to what is observed, and that therefore the H2O2 generation must occur at equilibrium, in a size-dependent manner, within the microdroplets, and that the levels generated can be extremely high (in the absence of light!).

The authors (correctly) point out that the details of the physics of H2O2 generation at the surface of the microdroplets are not fully understood, but that the observed correlation is compelling and has a plausible link to the seasonality of respiratory diseases.Although I feel excited about this potentially exciting link between fundamental science and the current COVID-19 pandemic, I have some hesitations on whether alternate explanations of the observations can be fully excluded:

1.A primary concern with the current observations is that RH_room (24-52%) and RH_mist (>99%) are very different. All droplet chemistry is taking place in the mist cloud, whereas conclusions relate to RH_room (where an isolated droplet would fully evaporate in a small fraction of a second).

2.The measurements were carried out over a period of many months and one wonders whether variables other than RH_room could have impacted the measurements.This reviewer would be less concerned if the data had been collected in a well-defined environment (e.g. glove box) while varying RH (in a randomized sequence) and keeping room temperature constant, while keeping track of the total amount of collected condensate per unit of time.

3.Can we fully exclude that differential evaporation of the condensed fluid became more efficient during later measurements, leading to artificial H2O2 enrichment not related to the droplet concentration (https://rasirc.com/resources/whitepapers/article-Cheating-Raoults-Law.pdf)?

4.The equilibrium H2O2 concentrations measured for the mist condensate are far higher than what is observed in atmospheric clouds in the absence of sunlight and it is not clear why this would be the case.

Review: Effect of Relative Humidity on Hydrogen Peroxide Production in Water Droplets — R0/PR2

Conflict of interest statement

Reviewer declares none.

Comments

Comments to Author: This manuscript describes the observation of increasing hydrogen peroxide concentrations as a function of relative humidity (RH) in microdroplets produced by ultrasonication. The authors surmise that this phenomenon may contribute to increased decay of microorganisms in droplets in a certain range of RH. The writing is very clear.

1. This is an interesting observation, although the data beg for additional points at higher RHs, which could readily be achieved by running the experiment in something like a Sigma Atmosbag with a humidifier inside it. Additional data points could support the purported relationship between RH and microorganism viability and could support arguments about size–dependence.

2. This seems like a simple experiment, but there could be a lot going on, as acknowledged in the discussion on p. 7 about the “Goldilocks effect.” Partitioning to the gas phase, the Kelvin effect, and differences in pH within droplets and between those of different sizes might also be considered. Additionally, do we know that the H2O2 concentration measured in mist collected in bulk equals that in the individual droplets?

3. p. 5: “The size of water droplets in the ultrasonically generated mist was characterized by light scattering…” Is the size distribution constant over the range of RH considered here? This is critical for trying to understand the RH effect on H2O2. The discussion of the Goldilocks effect seems to assume that the droplets are smaller at lower RH. We need to know how much smaller they are in this experiment.

4. p. 6: “It is possible that the higher hydrogen peroxide concentration reported in this study arises in part from ultrasonic cavitation…” This seems very likely. The claim “this should only enhance the background” suggests that the background is higher than anything added by ultrasonication. How do you know? I agree that this does not explain the variation with RH.

Recommendation: Effect of Relative Humidity on Hydrogen Peroxide Production in Water Droplets — R0/PR3

Comments

Comments to Author: Reviewer #1: This manuscript describes the observation of increasing hydrogen peroxide concentrations as a function of relative humidity (RH) in microdroplets produced by ultrasonication. The authors surmise that this phenomenon may contribute to increased decay of microorganisms in droplets in a certain range of RH. The writing is very clear.

1. This is an interesting observation, although the data beg for additional points at higher RHs, which could readily be achieved by running the experiment in something like a Sigma Atmosbag with a humidifier inside it. Additional data points could support the purported relationship between RH and microorganism viability and could support arguments about size–dependence.

2. This seems like a simple experiment, but there could be a lot going on, as acknowledged in the discussion on p. 7 about the “Goldilocks effect.” Partitioning to the gas phase, the Kelvin effect, and differences in pH within droplets and between those of different sizes might also be considered. Additionally, do we know that the H2O2 concentration measured in mist collected in bulk equals that in the individual droplets?

3. p. 5: “The size of water droplets in the ultrasonically generated mist was characterized by light scattering…” Is the size distribution constant over the range of RH considered here? This is critical for trying to understand the RH effect on H2O2. The discussion of the Goldilocks effect seems to assume that the droplets are smaller at lower RH. We need to know how much smaller they are in this experiment.

4. p. 6: “It is possible that the higher hydrogen peroxide concentration reported in this study arises in part from ultrasonic cavitation…” This seems very likely. The claim “this should only enhance the background” suggests that the background is higher than anything added by ultrasonication. How do you know? I agree that this does not explain the variation with RH.

Reviewer #2: The manuscript expands on the earlier QRB report by Dulay, Zare, and co-workers on the antimicrobial effect of spontaneously generated H2O2 in microdroplets.Here, the authors demonstrate that the H2O2 concentration in fluid from condensed droplets scales roughly linearly with room relative humidity (RH_room) and interpret this observation as a potential (perhaps plausible) explanation for the seasonality of respiratory diseases.Indeed, virus viability lifetime in aerosolized droplets is known to depend on RH_room and solution chemistry is likely to play a role in this viral inactivation.The alternate explanationthat RH_room-dependent osmotic bursting (Marr) applies is likely also true, but would lead to a very rapid inactivation during the first few seconds that a virus-droplet reaches its pseudo-equilibrium size after becoming airborne, but not to the slow decay in virus viability that has been documented for much longer time scales.Hence, H2O2-mediated inactivation which only will take place if the aerosolized droplet doesn't fully desiccate plausibly plays a plausible role in this process.

The authors correctly point out that the effective humidity in the droplet cloud differs from RH_room but argue that there is a relation between the two, which is undoubtedly true.The authors also argue that differential evaporation of the droplet would increase at lower RH_room (because the vapor pressure of H2O2 is far lower than that of H2O), opposite to what is observed, and that therefore the H2O2 generation must occur at equilibrium, in a size-dependent manner, within the microdroplets, and that the levels generated can be extremely high (in the absence of light!).

The authors (correctly) point out that the details of the physics of H2O2 generation at the surface of the microdroplets are not fully understood, but that the observed correlation is compelling and has a plausible link to the seasonality of respiratory diseases.Although I feel excited about this potentially exciting link between fundamental science and the current COVID-19 pandemic, I have some hesitations on whether alternate explanations of the observations can be fully excluded:

1.A primary concern with the current observations is that RH_room (24-52%) and RH_mist (>99%) are very different. All droplet chemistry is taking place in the mist cloud, whereas conclusions relate to RH_room (where an isolated droplet would fully evaporate in a small fraction of a second).

2.The measurements were carried out over a period of many months and one wonders whether variables other than RH_room could have impacted the measurements.This reviewer would be less concerned if the data had been collected in a well-defined environment (e.g. glove box) while varying RH (in a randomized sequence) and keeping room temperature constant, while keeping track of the total amount of collected condensate per unit of time.

3.Can we fully exclude that differential evaporation of the condensed fluid became more efficient during later measurements, leading to artificial H2O2 enrichment not related to the droplet concentration (https://rasirc.com/resources/whitepapers/article-Cheating-Raoults-Law.pdf)?

4.The equilibrium H2O2 concentrations measured for the mist condensate are far higher than what is observed in atmospheric clouds in the absence of sunlight and it is not clear why this would be the case.

Review: Effect of Relative Humidity on Hydrogen Peroxide Production in Water Droplets — R1/PR4

Conflict of interest statement

Reviewer declares none.

Comments

Comments to Author: The revised manuscript largely addresses my prior concerns and the authors correctly point out the caveats and open questions that remain to be addressed in future work.It is beyond doubt that the manuscript describes new and very interesting findings regarding conditions that impact H2O2 concentrations in microdroplets, which could have important consequences for virus viability in airborne respiratory droplets.Whether to go ahead with publishing the current work before carrying out the possibly pain-staking measurements in a more controlled environment (I don't expect much of a change in the results) is an editorial decision.I'm sure the readership of QRD will find the work of high interest, although I'm also sure the opinions on it will span the entire spectrum.

A few trivial points:

1. P.5 "maximum droplet diameter is 6.71 um".I presume the authors mean to say that the size distribution fits a lognormal function that peaks at 6.71 um?

2. The statement "production of hydrogen peroxide in droplets formed by spraying water (Lee et al., 2019)" strictly speaking is not really experimentally demonstrated by Lee et al.That study demonstrates that H2O2 is generated when water condenses and forms microdroplets, a non-equilibrium process.

3. The statement "The %RH in the mist is not expected to be the same as the %RH in the surrounding air" is strictly speaking correct but suggests that the difference may be minor.If the mist is near equilibrium, it most certainly must be above 99%.So perhaps it would be more appropriate to write something like "The %RH in the mist is expected to be much higher than the %RH in the surrounding air, but its rate of evaporation, and thereby its deviation from being saturated, must depend on %RH of the surrounding air"?

Review: Effect of Relative Humidity on Hydrogen Peroxide Production in Water Droplets — R1/PR5

Conflict of interest statement

Reviewer declares none.

Comments

Comments to Author: The authors have addressed the reviewers' comments satisfactorily. The new paragraph at the beginning of the Results and Discussion is helpful for interpreting the study. The expanded discussion of the dynamics of microdroplets in the system aids interpretation of the results.

Recommendation: Effect of Relative Humidity on Hydrogen Peroxide Production in Water Droplets — R1/PR6

Comments

Comments to Author: Reviewer #2: The authors have addressed the reviewers' comments satisfactorily. The new paragraph at the beginning of the Results and Discussion is helpful for interpreting the study. The expanded discussion of the dynamics of microdroplets in the system aids interpretation of the results.

Reviewer #3: The revised manuscript largely addresses my prior concerns and the authors correctly point out the caveats and open questions that remain to be addressed in future work.It is beyond doubt that the manuscript describes new and very interesting findings regarding conditions that impact H2O2 concentrations in microdroplets, which could have important consequences for virus viability in airborne respiratory droplets.Whether to go ahead with publishing the current work before carrying out the possibly pain-staking measurements in a more controlled environment (I don't expect much of a change in the results) is an editorial decision.I'm sure the readership of QRD will find the work of high interest, although I'm also sure the opinions on it will span the entire spectrum.

A few trivial points:

1. P.5 "maximum droplet diameter is 6.71 um".I presume the authors mean to say that the size distribution fits a lognormal function that peaks at 6.71 um?

2. The statement "production of hydrogen peroxide in droplets formed by spraying water (Lee et al., 2019)" strictly speaking is not really experimentally demonstrated by Lee et al.That study demonstrates that H2O2 is generated when water condenses and forms microdroplets, a non-equilibrium process.

3. The statement "The %RH in the mist is not expected to be the same as the %RH in the surrounding air" is strictly speaking correct but suggests that the difference may be minor.If the mist is near equilibrium, it most certainly must be above 99%.So perhaps it would be more appropriate to write something like "The %RH in the mist is expected to be much higher than the %RH in the surrounding air, but its rate of evaporation, and thereby its deviation from being saturated, must depend on %RH of the surrounding air"?

Recommendation: Effect of Relative Humidity on Hydrogen Peroxide Production in Water Droplets — R2/PR7

Comments

No accompanying comment.

Recommendation: Effect of Relative Humidity on Hydrogen Peroxide Production in Water Droplets — R3/PR8

Comments

No accompanying comment.